en PLEASE READ AND SAVE ALL THESE INSTRUCTIONS! Important safety instructions • Prior to using the appliance, read through the in structions for complete use and retain in a safe place for later reference. • WARNING – Only use the Ultrasonic indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury. • Connect the unit only to alternating current with voltage according to the rating label.
1 4 7 2 5 8 3 6 9 en 7
en Foreword Congratulations on choosing the Ultrasonic Humidifier AOS U600 / U650 from AIR-O-SWISS! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging eyes? • Encourages infections and illnesses of respiratory system? • Causes weariness, tiredness and poor concentration? • Stresses household pets and house plants? • Encourages the formation of dust and the electrostatic charging of textiles made of synthetic fibers, carpet
Description of the appliance en Mist outlet (rotating) Water tank Evaporation chamber Demineralization cartridge Water tank cap Brush Ionic Silver Stick® Membrane Nebulizer space Control panel Power Plug Main body 9
en Setting up Finding the ideal location for your unit: • Do not place the humidifier directly next to a heating vent or on a floor with floor heating. The moisture of the mist can damage the floor surface (6) (see Safety Instructions). • The unit should be placed in an elevated position (7), e.g. on a table, chest, etc. at least 3 ft off the floor. • The mist outlet must not be pointed directly at plants, furniture, or other objects (12). Keep distance of at least 20 inches (50cm).
Filling the tank Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! 14 17 15 18 16 19 en Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The empty indicator light comes on showing tank is empty. • Remove the water tank from the base and unscrew the water tank cap (14). • Make sure that no foreign objects are in the water tank.
en Operation AOS U600 B C) Operation with pre-heating (warm mist) E D A C A) On/Off Dial and regulation of mist output Turning the right-hand rotary dial clockwise switches the appliance on and at the same time regulates the mist out put from low to high. B) Hygrostat (setting the humidity level) The desired humidity level can be set by turning the lefthand rotary dial clockwise. A relative humidity of between 40% and 60% is recommended.
Operation AOS U650 L B C) Timer H G M D Using button C, the operation time can be set adjusta ble between 1 and 8 hours or CO (continuous operation). Symbol G shows the operating period that has been set (1h/2h/3h/4h/5h/6h/7h/8h/CO). The display will automati cally show the current humidity after a few seconds. D) Mist output (regulating mist output) TIME CURRENT By repeatedly pressing button D you can control the mist output.
en Cleaning/Maintenance Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! 20 RRENT Caution – risk of electric shock and damage of the product! • Switch off the appliance (20) and unplug it from the socket before cleaning it (21). • Clean the water tank and the base regularly. Use water only, no detergents (22). • Use AIR-O-SWISS EZCal custom cleaning and descaling agent only to remove deposits from the membrane re gularly (23).
• Only use the brush to clean the membrane. This should be done once a week. Only use the soft-bristle portion of the brush (26). • Change the water in the tank at least once a week if water is standing for more than a week. • To remove the mist outlet (27): Twist the tabs on the mist outlet to either the right or the left. Align the tabs and arrow on the mist outlet with the arrows on the ring around the mist outlet. Pull up on the mist outlet once the arrows are aligned.
en Replacement of the demineralization cartridge Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! The water tank is equipped with a demineralization cart ridge. This cartridge has to be replaced every 2 – 3 months. If the water is very hard, it may be necessary to replace the cartridge earlier. White dust around the device is a sure sign that the cartridge needs replacing.
34 35 38 en 43 36 39 40 44 37 41 42 45 17
en Storing the appliance for extended periods Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, in a dry place away from high temperatures. Legal notice The humidifier is cUL-listed. Subject to technical change. The instructions for use are protected by copyright © PLASTON AG. Technical data Electrical voltage Power consumption up to Humidity output up to Suitable for rooms up to Dimensions (LxWxH) 120 V / 60 Hz 40 W / (125 W*) 3.
General Humidifier Questions Q. Why isn’t there enough moisture in my room? A. How often do you run the unit? If the unit is only run at night, then during the day the moisture level will drop if moisture is not constantly added to the air. Q. Do you leave your door open or closed when the unit is running? A. a) By leaving the door open, this allows moisture to leave the room and go into other areas of the house.
en placed at least 3 feet off the floor, the mist will have the opportunity to evaporate before hitting the floor. Q. Water does not go into the tank. A. In order to fill the tank, it must be turned upside down. The cartridge is placed on the water tank cap. Do not pour water in the tube which is the mist outlet. Q. White dust is emitted from the unit A. White dust particles are minerals that are broken up in tiny pieces by the ultrasonic process.
Q. Water tank cap is too tight to unscrew A. This could be a cause of the air pressure within the water tank. Depress the spring on the bottom of the water tank cap to release air from the water tank. Continue to do this until you are able to unscrew the water tank cap. Q. Unit is running intermittently. A. How long has it been since the contents of the cart ridge were replaced? If 2-3 months have passed, it is time to replace the contents of the cartridge.
en 22
AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland 36485-00 Please check our website www.airoswiss.net for further information.