- Airlink+ Network Router User Manual

Host RJ-11 IP Gateway User Guide, version 40
APPENDIX B AT Commands
In addition to the web-based interface, you can use some typed AT Commands with the Host RJ-11
IP Gateway. To enter AT commands, you need to be connected to the device via telnet or by using
the RJ-11 port as you would a standard analog modem.
All AT command strings, with the exception of the break sequence (“+++”) and the repeat com-
mand (“A/”), must be terminated with the command line termination character, defined in S3
(default is CR). All characters before 'AT' are ignored. Unsupported commands are ignored and
generate an “OK” result code. Multiple commands may be combined on a single line, however the
AT command string is currently limited to 40 characters.
Example: AT&FE0V0
Command Function Response
/ Repeat last command Varies
Note: Command executes upon “/” character,
CR not needed.
<blank> Attention OK(0)
A Answer OK(0), NO CARRIER(3)
D Dial CONNECT(1), NO CARRIER(3)
If suffixed with “;” character, will return to com-
mand mode upon connection.
En Echo Mode
0=Turn command echo off
1=Turn command echo on (default)
OK(0)
Hn Hang-up or Terminate connection.
Optional argument has no function
OK(0)
In Information
0=Serial Port Speed
3= Model and Version
Varies
Actual value equals current port speed
NDS/5102 (2 Port, RJ-45) v01A
O Return to data mode from command
mode
Qn Result Codes
0=Enable result codes (default)
1=Supress result codes
OK(0)
<blank>