PERFORMANCE DATA & PRESSURE CURVES
5.1.6.2 Heating
Discharge Pressure VS.Outdoor Temp
16
18
20
22
24
26
28
30
32
34
36
38
40
-10-5 0 5 101520
Outdoor Temp.( WB
o
C )
Discharge Pressure(Bar[g])
25 DB (ºC)
20 DB (ºC)
15 DB (ºC)
5.4 HGF024 / HHF024 // YGF024
5.4.1 Cooling Capacity (kW)
Entering Air WB/DB ID Coil(
o
C)
Entering Air
DB OD Coil(
o
C)
Data
15/21 17/24 19/27 21/29 23/32
TC
6.28 6.62 6.82 6.99 7.14
20 SC
4.14 4.36 4.54 4.67 4.76
PI
1.46 1.47 1.47 1.48 1.48
TC
5.94 6.41 6.74 6.95 7.11
25 SC
4.03 4.28 4.51 4.64 4.72
PI
1.58 1.59 1.60 1.61 1.62
TC
5.55 6.05 6.53 6.77 6.97
30 SC
3.90 4.15 4.41 4.54 4.63
PI
1.70 1.73 1.74 1.76 1.77
TC
5.14 5.58
6.16
6.46 6.77
35 SC
3.71 3.98
4.31
4.43 4.52
PI
1.84 1.87
1.90
1.91 1.93
TC
4.68 5.09 5.55 6.07 6.39
40 SC
3.50 3.76 4.08 4.21 4.29
PI
1.98 2.01 2.05 2.07 2.09
TC
4.06 4.44 4.88 5.39 5.81
46 SC
3.22 3.45 3.72 3.85 3.93
PI
2.17 2.20 2.25 2.28 2.31
5-8 SM HGFHHF 1-A.1 GB