Characteristics Units Cooling Heating
Capacity (4) kW 3.22 3.52
Power input (4) kW 1.00 0.97
EER (Cooling) or COP(Heating) (4) W/W 3.21 3.61
Energy efficiency class A A
V 220-240
Ph 1
Power supply
Hz 50
Rated current A 4.7 4.6
Power factor 0.92 0.92
Prated (IDU+ODU) W 1450
Circuit breaker rating A 16A
Fan type & quantity Crossflow x 1
Cooling SH/H/M/L RPM 1350/1250/1100/950
Fan speeds
Heating SH/H/M/L RPM 1350/1250/1100/950
Air flow (1) SH/H/M/L m3/hr 550/500/420/350
External static pressure Min Pa 0
Sound power level (2) SH/H/M/L dB(A) 50/48/45/42
Sound pressure level(3) SH/H/M/L dB(A) 40/38/35/32
Moisture removal l/hr 1.0
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 790x265x177
Net Weight kg 9
Package dimensions WxHxD mm 870x355x248
INDOOR
Packaged weight kg 12
Refrigerant control Capillary
Compressor type, model Rotary, LANDA- QXA-B120C150
Fan type & quantity Propeller(direct) x 1
Fan speeds H RPM 850
Air flow H m3/hr 1800
Sound power level H dB(A) 62
Sound pressure level(3) H dB(A) 52
Dimensions WxHxD mm 798x540x320
Net Weight kg 35
Package dimensions WxHxD mm 825x580x355
Packaged weight kg 40
Refrigerant type R410A
Standard charge kg(4m) 0.76
Additional charge g/m 30g/m(4m<L<20m)
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 1/2"(12.7)
Max.tubing length m. Max. 20
OUTDOOR
Connections
between units
Max.height difference m. Max. 10
Operation control type Remote control
(1)Airflow in ducted units; at nominal external static pressure.
(2)Sound power in ducted units is measured at air discharge.
(3)Sound pressure level measured at 1-meter distance from unit.
(4)Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units).