Troubleshooting guide
This air conditioner is equipped with a self-diagnosis function to help you
identify potential problems. Should you encounter problems with your air
conditioner, contact our after sales support centre using the details on the
bottom of the page. However, before calling for service, consult the self-
diagnosis information below.
Self-check
information
Indicator light self-check
code
Digital self-
check code
Defrost indication Blinks once per second Indicates
“dF”or heating
icon blinks
Anti cold wind Blinks once per second Fan motor
picture not
running
Room temperature
sensor fault
Blinks once every 8 seconds E2
Coil temperature sensor Blinks twice every 8 seconds E3
Indoor fan fault Blinks 3 times every 8 seconds E8
Outdoor feedback Blinks 6 times every 8 seconds E5
External feedback fault Blinks 7 times every 8 seconds E7
Open the door fault Blinks 3 times every 8 seconds E0
Outdoor tube
temperature sensor
faults
Blinks 4 times every 8 seconds E1
(EEPROM)
Communication failures
Blinks 6 times every 8 seconds E6
Outdoor temperature
exceeds scope (too
cold)
Blinks once per second FF