Installation Instructions

9
Installation (Cont.)
After Sales Support
1300 886 649 | info@tempo.org
Installation of the indoor unit
The pipes can be connected as illustrated in Fig.9. When the pipes are
connected to exit at the sides of the unit, a groove for the pipes has to be
opened at the proper place on the base stand.
Installing the wall-mounting plate
Fix the wall-mounting plate firmly on the wall with screws. Make sure the
plate is installed level, a slanted wall-mounting plate might jeopardise the
smooth discharge of condensation water.
*
Rear outlet
*Left rear outlet
*Left outlet
*
Right outlet
*Bottom outlet
Fix with a tape
Wall cap
Wall pipe
Interior
Exterior
5-10mm
lower
(1/5-2/5")
Wall
Pipelines of indoor unit
Drain pipe
Rear pipe
Bottom hooks
Hook supports
Top hooks
Fig.9
Fig.10
Fig.11
Fig.12
Drilling holes
Drill holes with a diameter of 65mm
slightly below the wall-mounting
plate, making sure the outer edge of
the hole is 5-10mm lower (Fig.10) so
that condensation water can flow out
smoothly.
Cut the pipe that penetrates the wall to
the proper length; it should be 3-5mm
longer than the wall thickness, then
insert the pipe as illustrated (Fig.10).
Installing the drain pipe
Install the pipes of the indoor unit
in accordance with the direction of
the wall holes. Wrap the pipes and
drain pipe tightly together with tape,
making sure that the drain pipe is
underneath the pipes (Fig.11). (When
the drain pipe passes the room interior,
some condensed water drops may
accumulate on the pipe surfaces if the
humidity is very high.)
Installing the indoor unit
Pass the connection wires, connecting
pipes and drain pipe through the wall
hole. Hang the indoor unit on the hooks
at the top of the wall-mounting plate
so that the hooks at the bottom of the
indoor unit match the hooks of the wall-
mounting plate (Fig.12).