Installation Guide

Important: Do not apply pressure directly to the
appliance manifold pipe when tightening supply
connections. The manifold pipe should be held
securely at the pressure regulator to prevent twisting.
Hold the pressure regulator with a wrench during the
tightening of the connection, or the manifold pipe may
be twisted and split and cause a dangerous leak.
Note: Check all piping connections in the unit for leaks.
Never use an open flame to check for gas leaks. Use a
soap solution, 75% water, 25% dishwashing soap. It is
possible for connections made at the factory to leak,
due to vibration encountered in transportation. Make
certain you have checked them all, and repair any
connections that leak.
The appliance and its individual shut-off valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig.
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig.
Electrical Shock Hazard.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Any additions, changes, or conversions required for
this appliance to meet the specific application needs
must be performed by a qualified service technician
in accordance with the manufacturer's instructions
and all relevant codes and regulations. Failure to
follow these instructions could result in serious injury
or property damage. The qualified professional
undertaking this work assumes responsibility for the
conversion.
DO NOT operate this appliance using a 2-prong
adapter or an extension cord. If only a 2-prong wall
receptacle is available, it is the consumer's personal
responsibility to have it replaced with a properly
grounded 3-prong wall receptacle installed by a
qualified electrician.
Severe shock or damage to the range may occur if
the appliance is not installed by a qualified installer or
electrician.
This appliance requires a 120V/60Hz power supply. It
is recommended to connect it to a 15-Amp or 20-Amp
power supply.
To reduce the possibility of gas leaks, apply Teflon tape
or a thread compound approved for use with LP or
natural gases to all threaded connections.
Install a manual gas line shut-off valve in the gas line in
an easily accessed location outside the range in the gas
piping external to the appliance for the purpose of
turning on or shutting off gas to the appliance.
Install a male 1/2" (30- or 36-inch range top) or 3/4"
(48-inch range top) flare union adapter to the 1/2" or
3/4" NPT internal thread elbow at the inlet of the
regulator. Use a wrench on the regulator fitting to avoid
damage.
Install a male 1/2" or 3/4" flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care
to secure the shut-off valve to keep it from turning.
Total Input Power is 14.1 kW (AN-2160), 20.8 kW
(AN-2161), 27.5 kW (AN-2162), 3 A for range tops. Total
Input Power is 23.4 kW (30" range), 30.2 kW (36"
range), 41.1 kW (48" range), 5 A for ranges. A dedicated
circuit protected by a minimum 15 to 20-amp time delay
fuse or circuit breaker is required.
For personal safety, it is essential that the appliance is
properly grounded.
The power supply must have the correct polarity.
Reverse polarity can result in continuous sparking of the
electrodes, even after flame ignition. If there is any
uncertainty about the power supply's polarity or
grounding, it should be checked by a qualified
electrician.
GAS CONNECTIONS (All Units)
ELECTRICAL DANGER
GAS LINE SHUT-OFF VALVE
WARNINGS:
cooking appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-pronged receptacle.
plug.
Caution: label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
Important Safety Information
10