Installation Guide

2”
4”
10.5”
2”
6.25”
Figure 2
Area allows for
with through-the-
wall connection
of pipe stub /
shut-off valve
and rear wall
120V outlet.
of pipe stub / shut-off valve.
Shortest connection
from hard pipe stub
location to range
hook-up.
To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate, or sustain
other damage.
MOBILE HOME - ADDITIONAL INSTALLATION
REQUIREMENTS:
The installation of this appliance must conform to the
Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280).
When such standard is not applicable, use the
Standard for Manufactured Home Installations, ANSI
A225.1/NFPA 501A, ANSI A119.2.2–1982, or with local
codes.
In Canada, the installation of this range must conform to
the current standards CAN/CSA-A240-latest edition,
CAN/CGA Z240.4.2, or with local codes.
MOBILE HOME INSTALLATIONS REQUIRE:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
The installation of appliances designed for recreational
park trailers must conform with state or other codes or, in
the absence of such codes, with the standard for
recreational park trailers, ANSI A119.5.
Explosion hazard conditions will exist unless
you perform ALL of the following:
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person ensure that
the gas pressure does not exceed 10" (25 cm) for range
tops or 14" (36 cm) for ranges, water column.
Examples of a qualified person include:
- Licensed heating personnel
- Authorized gas company personnel
- Authorized service personnel
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform to all local
codes and ordinances. In the absence of local codes,
the installation must conform to the American National
Standard, National Fuel Gas Code ANSI Z223.1 /
NFPA 54 - latest edition, or CAN/CGA B149 - latest
edition. In Canada, the installation must conform to the
current Natural Gas Installation/code, CAN 1-1.1-M81,
and with local codes where applicable. This appliance
has been design-certified according to ANSI
Z21.1b-201, latest edition.A statement of the maximum
gas supply pressure in accordance with the inlet
pressure rating of the gas appliance pressure regulator
supplied.
IMPORTANT: Leak testing of the appliance must be
conducted according to the manufacturer's instructions.
The appliance should be connected to the supply line
with 1/2-inch black iron pipe or a certified flexible type.
Stove connector. To prevent gas leaks, put an approved
sealing compound that is resistant to liquefied petroleum
gases on all threaded connections.
Gas supply should be located near the opening for this
appliance (see Figure 2, ranges only):
NATURAL GAS:
This appliance is designed for use with natural gas or,
after proper conversion, for use with LP gas.
This appliance is factory set for use with natural gas.
The model/serial rating plate has information on the
types of gas that can be used. If the types of gas listed
do not include the type of gas available, check with the
local gas supplier.
LP GAS CONVERSION:
Conversion must be done by a qualified service
technician.
No attempt should be made to convert the appliance
from the gas specified on the model/serial rating plate
for use with a different gas without consulting the
serving gas supplier.
INSTALLATION WARNINGS
GAS DANGER
Types of Gas
Important Safety Information
9