2. AIR FLOW DIRECTION CONTROL
l This function is to swing the louver up and down automatically and to set it at a
desired position.
l The procedure is as following.
F Press the ON/OFF button to operate the appliance. The louver will swing
automatically to the default position.
F Press the SWING button to swing the louver up and down automatically.
F Repress the SWING button to stop the louver at a desired position.
l The louver is controlled by a step motor. The different default position of different
modes is as following:
F The louver can swing from 0° to 110°.
F The louver closes at 0°.
F The louver swings from 25° to 65° with an automatic setting point of 45° during
COOLING operation.
F The louver swings from 10° to 30° with an automatic setting point of 30° during
DRY operation.
F The louver swings from 45° to 98° with an automatic setting point of 85° during
HEATING operation.
F The louver swings from 45° to 98° with an automatic setting point of 85° during
FAN only operation.
3. COOLING MODE OPERATION
l When the COOLING mode operation is selected without setting temperature, the
appliance will set the preset temperature at 26
o
C automatically with the AUTO
FAN speed.
l When selecting the COOLING mode operation, the appliance will operate ac-
cording to the setting by the remote controller and the operation diagram is as
following: