Service manual

14
Model No: AC-S10CK_S10HK
Version 1.0
4. DRY MODE OPERATION
l The appliance starts as COOLING operation. If 3 minutes elapses after starting,
the appliance will sense the intake air temperature and minus 1.5
o
C as the
setting temperature.
l During DRY operation, the compressor ON when temperature is the setting
temperature plus 1
o
C. The compressor OFF when temperature is the setting
temperature minus 1
o
C. The setting temperature can only be adjusted by 2
o
C
up and down.
l When the appliance operates at DRY mode, the indoor motor speed is LOW.
5. HEATING MODE OPERATION (ONLY AVAILABLE FOR HEAT PUMP)
l The appliance will operate at the setting by the remote controller and the opera-
ROOM TEMP.
SET TEMP.+1¡æ
(COMP.ON)
SET TEMP.-1¡æ
(COMP. OFF)
Indoor fan motor
speed
Compressor
Outdoor fan motor
set
speed
low
speed
set
speed
low
speed
set
speed
ON OFF ON OFF ON
ON OFF ON OFF ON
More than
3 mins
More than
3 mins
set set