Service manual

27
Model No: AC -S10CK_S10HK
Version 1.0
Pipe Size Torque
Liquid Side(φ6 or 1/4 inch) 1.8 kg.m
Liquid Side (φ10 or 3/8 inch) 3.5 kg.m
Liquid Side(φ12 or 1/2 inch) 5.5 kg.m
Gas Side (φ10 or 3/8 inch) 3.5 kg.m
Gas Side(φ12 or 1/2 inch) 5.5 kg.m
Gas Side(φ16 or 5/8 inch) 7.5 kg.m
Gas Side(φ19 or 3/4 inch) 10.0 kg.m
l Wrap the insulation material around the connecting portion.
4. CONNECTING PIPINGS AND THE CABLE TO OUTDOOR UNIT
l Connecting the piping to outdoor unit
F Align the center of the piping and sufficiently tighten the flare nut with fingers.
F Finally, tighten the flare nut with torque wrench until the wrench clicks.
Downloaded from AC-Manual.com Manuals