Service manual

41
Model No: AC-S10CK_S10HK
Version 1.0
refrigerant.
F If the system can not be charged with the specified amount of refrigerant, it can
be charged with a little at a time (approximately 150g each time) while operating
the air conditioner in the cooling cycle. However, one time is not sufficient, wait
approximately 1 minute and then repeat the procedure (pumping down pin).
F This is different from previous procedures. Because you are charging with liquid
refrigerant from the gas side, absolutely do not attempt to charge with larger
amounts of liquid refrigerant while operating the air conditioner.
l Immediately disconnect the charge hose from the 3-way valveā€™s service port.
F Stopping partway will allow the gas to be discharged.
F If the system has been charged with liquid refrigerant while operating the air
conditioner before disconnecting the hose.
l Mount the valve caps and service port cap.
F Use torque wrench to tighten the service port cap to a torque of 1.8kg.m.
F Be sure to check for gas leakage.