CHAPTER 2: SPECIFICATIONS
(SEE APPENDIX A)
CHAPTER 3: OPERATING RANGE
1. TEMPERATURE RANGE FOR T1 CLIMATE AIR CONDITIONER
l The preset temperature of the appliance ranges from 18
o
C to 32
o
C.
l The ambient temperature of the cooling only air conditioner ranges from 18
o
C to
43
o
C.
l The ambient temperature of the heat pump ranges from –7
o
C to 43
o
C.
l The rated cooling operation test condition is as following.
Indoor DB/WB temperature: 27
o
C /19
o
C
outdoor DB/WB temperature: 35
o
C /24
o
C
l The rated heating operation test condition is as following.
l indoor DB/WB temperature: 20
o
C /Max.15
o
C
l outdoor DB/WB temperature: 7
o
C /6
o
C
2. TEMPERATURE RANGE FOR T3 CLIMATE AIR CONDITIONER
l The preset temperature of the appliance ranges from 18
o
C to 32
o
C .
l The ambient temperature of the cooling only air conditioner ranges from 21
o
C to
52
o
C.
l The rated cooling operation test condition is as following.
Indoor DB/WB temperature: 27
o
C /19
o
C
outdoor DB/WB temperature: 35
o
C /24
o
C