User`s manual

3
9534 Com-Pax-ial 8” Blower
9534-15 Com-Pax-ial 8” Blower with 15’ Ducting and Canister
9534-25 Com-Pax-ial 8” Blower with 25’ Ducting and Canister
The following are available with a 12-volt DC motor, models include:
9506 Standard Axial 8” Blower
9506-01 Standard Axial 8” Blower with 15’ Ducting Canister
9506-25 Standard Axial 8” Blower with 25’ Ducting & Canister
9537 Com-Pax-ial 8” Blower
9537-15 Com-Pax-ial 8” Blower with 15’ Ducting and Canister
9537-25 Com-Pax-ial 8” Blower with 25’ Ducting and Canister
SAFETY PRECAUTIONS
DO NOT operate blower until the operator completely comprehends the contents of this
manual.
The blower is a specialized type of powered equipment, designed for a specific job
function and requires adequate and thorough instruction BEFORE it is operated. Each
person must receive adequate professional instruction regarding proper operation.
Read and understand this User Manual and the material supplied by the motor
manufacturer. Refer to OSHA 2207, for job safety and health rules and regulations
(1926 and 1910) covering construction.
DO NOT set-up or operate a blower without verifying the location classification and
match or exceed location requirements for blower type. Certain job site locations may
be classified as hazardous because of explosive concentrations of gas, vapor or dust in
the atmosphere. The National Electric Code (NEC) divides these locations into Classes
and Groups according to the type of explosive agent. For specific information, consult
the NEC, Section 500-504 and 510-517. Use Allegro Explosion-Proof Blowers for
operation in an explosive or flammable atmosphere that match or exceed location
requirements. The use of any other blower not designed for use in a Hazardous
Location may result in personal injury or death.
DO NOT use an undersized wire size on electrical power cable or extension cords if
used. This will adversely limit the starting and load carrying capabilities of the motor.
Always use minimum AWG wire sizes for motor branch circuits. Consult the National
Electric Code Tables, Article 400, for specific information.
DO NOT operate the blower without the inlet and outlet screens properly secured and in
place. Replace screens with factory replacements (OEM). The screen grid must
comply with current OSHA regulations regarding protective enclosures to prevent
personal injury to the operator(s). Ensure the structural integrity of the screens will
allow them to serve their protective function. Keep both screens free from obstructions
and debris to allow maximum airflow.