User's Manual

Overview
26
Applications for the AT-MC606 VDSL Network Extender
The AT-MC606 VDSL Network Extender is designed to be used in pairs to
extend Ethernet traffic over existing coaxial cables in a building. One
AT-MC606 is configured as the subscriber unit and the second unit is
configured as the provider unit. You must manually configure these units
as a subscriber or provider unit when installed.
If you plan to install multiple AT-MC606s in a rack or on a desktop, the
AT-MCR12 chassis can accommodate up to 12 units. The DC power for
all of the AT-MC606s is provided by an internal power supply within
the AT-MCR12 chassis.
Multiple Dwelling
Unit (MDU)
Topology
The AT-MC606’s can be used is in multi-dwelling units (MDU), multi-
tenant buildings (MTU) or in the hospitality industry, such as airports,
hotels, and convention centers. For example, Figure 5 illustrates a point-
to-point topology for an MDU building where internet services are
delivered to each room using VDSL via the building’s coaxial cable wiring.
Figure 5. Multiple Dwelling (MDU) Point-to-Point Topology
An AT-MC606 Subscriber unit is installed in each guest room while the
corresponding AT-MC606 Provider units are located in the building’s
central equipment room and are individually assigned to each office.
The Provider units are rack mounted together in AT-MCR12 chassis and
their Ethernet ports are connected via an Ethernet LAN to the building’s
internet service. Both Subscriber and Provider units are configured
1357911 1315171921R23R
2 4 6 8 10 12 14 16 18 20 22R 24R
CLASS 1
LASER PRODUCT
AT-9424T
1 3 57 9 111315171921R23R
2 4 6 8 10 12 14 16 18 20 22R 24R
TERMINAL
PORT
FAULT
MASTER
POWER
STATUS
SFP
21 22 23 24
L/A
D/C
D/C
L/A
D/C
L/A
1000 LINK / ACT
HDX /
COL
FDX
10/100 LINK / ACT
PORT ACTIVITY
21
22
23
24
SFP
L/A
Gigabit Ethernet Switch
MCR12
POWER
ADSL
AT-AR440
1933
Subscriber Unit
Guest Room
Subscriber Unit
Guest Room
Subscriber Unit
Guest Room
Subscriber Unit
Guest Room
Internet
Building Equipment Room
12 AT-MC606
Provider Units
mounted in an
AT-MCR12 Chassis
Existing Coaxial
Cabling in Building
ASYMFASTSCBR 6dB
SYM
INTL
PROV
9dB
VDSL CONFIG
10Base-T/
100Base-TX
LNK/ACT
100M
PWR
VDSL LINE
LINK
RATE
PROV
SCBR
AT-MC606
VDSL EXTENDED ETHERNET
ASYMFASTSCBR 6dB
SYM
INTL
PROV
9dB
VDSL CONFIG
10Base-T/
100Base-TX
LNK/ACT
100M
PWR
VDSL LINE
LINK
RATE
PROV
SCBR
AT-MC606
VDSL EXTENDED ETHERNET
ASYMFASTSCBR 6dB
SYM
INTL
PROV
9dB
VDSL CONFIG
10Base-T/
100Base-TX
LNK/ACT
100M
PWR
VDSL LINE
LINK
RATE
PROV
SCBR
AT-MC606
VDSL EXTENDED ETHERNET
ASYMFASTSCBR 6dB
SYM
INTL
PROV
9dB
VDSL CONFIG
10Base-T/
100Base-TX
LNK/ACT
100M
PWR
VDSL LINE
LINK
RATE
PROV
SCBR
AT-MC606
VDSL EXTENDED ETHERNET
. . . . . . . . . . .
.
.
.