operation manual

78Art.Nr. 20497503 02/2013 79Art.Nr. 20497503 02/2013
Preparations:
Slider can be moved only after the locking screw (No.10 item of the
Nomenclature) is loosened.
Wipe all the measuring faces and caliper clean. using a damp cloth.
Check to see if all the buttons. switches and the LCD display respond well.
Basic measuring methods:
Loosen the locking screw.
Switch the unit on with a press on „ON“ button.
Then select the unit system needed by pressing Inch! Metric button.(Each time
the button is pressed. inch and metric digits will be displayed alternatively).
Apply normal measuring pressure on slider to close the external measuring jaws.
Then press „zero· button to reset the display to zero.
A
18.58
OFF ON
mm/inch
ZERO
mm
18.58
C
OFF ON
mm/inch
ZERO
mm
18.58
B
18.58
OFF ON
mm/inch
ZERO
mm
18.58
A. Internal dimensions B. External dimensions C. Steps