Data Sheet

Product Specification Sheet APS654 - Rev. 07/2013
NC110A Audible / Visual 50 L.E.D. Nurse-Call Master (no intercom)
42 Central Drive Farmingdale NY 11735-1202 Phone: (631) 777-5500 Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 Web: AlphaCommunications.com Email: info@alphacommunications.com
Copyright© 1998-2014 Alpha Communications® - All Rights Reserved.
Due to continuous product improvement, all colors, sizes, materials, finishes and specifications are subject to change without notice.
< Previous (APS653) Next (APS655) >
Architects' And Engineers' Specifications
The annunciator/control panel(s) shall be Alpha Communication
/ TekTone® NC110A or approved equal, with button-controlled
circuits for tone on/off (ROUTINE calls only), tone test and tone
volume control, plus indicator LEDs for EMERGENCY and
ROUTINE calls. Fifty (50) indicator LEDs shall be provided for
room annunciation, with removable labels to allow for custom point
markings. An audible signal shall be provided via an electronic
oscillator driving an enclosed 45-ohm speaker. An N/O isolated
relay contact shall be available for ancillary off-board call handling.
The unit shall use convenient plug-in connectors to allow for ease
of wiring rough-in and shall connect via two (2) supplied 6-
foot cables. The housing shall be high-impact, flame-
retardant (UL® 94V-0) Black plastic with a membrane-type
switch for control buttons and LEDs, and shall be desk mounted.
The NC110A shall be UL® 1069 Listed.
Contractor shall observe all local and national electrical and
building codes.
NC110A Series Audible-Visual 50 LED Nurse-Call Master
The Alpha Communication/ TekTonNC110A Audible Visual
Nurse Call Annunciator/Control Master provides for audible and
visual call indication without the use of intercom communications.
A basic nurse-call system may consist of an NC110A
annunciator/control master, room call stations, emergency call
stations, dome lights, zone lights, control unit and power supply
equipment. Emergency signals are identified at
the annunciator/control panel by a rapid flashing of the
associated station indicator LED, call LED and emergency LED; in
addition to a rapid pulsating tone. Routine calls are indicated by
the steady illumination of the station selector LED, call LED, and a
slow pulsating tone. The tone may be canceled for normal calls
by depressing the TONE ON/OFF button. EMERGENCY calls
take precedence over ROUTINE calls. Call signals can be canceled
at point of origin only. Tone on/off and tone test functions
are button selectable from the control panel, and three (3) levels
of tone volume are button selectable with LED indication.
Indicator LEDs signal the presence of EMERGENCY or ROUTINE
calls. The NC110A has a maximum capacity of 50 selector
points. Multiple NC110A masters may be used together for
larger system capacities. All selector LEDs, indicator LEDs and
control buttons are included on a membrane-type switch mounted
on a telephone-sized plastic housing. An N/O open isolated
relay contact output for ancillary off-board call handling is
also included.
Features
UL® 1069 Listed
Electronic tone circuit with volume control
Tone on/off and tone test functions
EMERGENCY and ROUTINE call signaling
Ideal for Hospital and Nursing Home Applications
50-point capacity with labels for custom marking
Spill-resistant membrane switch
Specifications
Dimensions:
8.50"w × 8.50"h × 3.00"d (216 mm ×
216 mm × 76 mm)
Power Requirement: 24 VDC, 650 mA
Construction:
Flame-retardant (UL® 94V0) Black
plastic with membrane switch
Connections: Keyed plug-in