User`s guide

MULTI-TASKER
8
on multiple cards or the same card can be
loaded.
Command Format: [OFFmCnUiP]
m = output number (m =1 to 16)
n = card ID No. (n = a slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
P = path
Example:
If 2 cards are at slot 4 and 8 of unit 3:
To enable output 1 and 2 of card 4 and output 3
and 4 of card 8 simultaneously, use the following
commands:
[OFF12C4U3P]
[OFF34C8U3P]
[SW]
If "F" is included use the [OFFmCnUiPF]
command or the [OFFmCnUiFP]
command.
[OFF…F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is zero.
Example:
[OFF1C4U3F]: if path is not set
[OFF1C4U3PF]: if path is set
7. [SW]
The switch command immediately connects
inputs and outputs, which were previously set ith
the path command on this card or any other
cards in the MT100-100.
Example:
[ON12C6U3P]
[ON34C10U3P]
[SW]
The system will return feedback as OK if the unit
ID is zero.
8. [WR]
This command groups multiple cards in the
MT100-100 Enclosure. Each unit contains a
maximum of nine groups.
Command Format: [WRCn…GkUi]
n = card ID No. (n = slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
Example:
To group card #4, 8, and 12 as group 5 of unit
#1, send the [WRC4C8C12G5U1] command.
After executing this command, card 4, 8, and 12
will be grouped as group 5 of unit 1.
OK or ER will be returned as feedback if "F" is
included at the end of a command string or if the
unit ID is zero.
9. [CLR]
This command clears the members for a single
group or for all nine groups.
[CLRCnUi]: for a single card
n = Card ID number (n = 1 to 19) (1 to 8 for
MT100-101 or 1 to 4 for MT100-106)
Ui = Unit ID number (i = 0 to 9)
Note that all outputs will be connected to input1.
[CLRGkUi]: for a group of cards
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
Example:
a) To clear group #1, send the [CLRG1U1]
command. This command clears the members
for the specified group only.
b) To clear all groups of unit 1, send the
[CLRGU1] command.
OK or ER will be returned as feedback if "F" is
included at the end of a command string or if the
unit ID is zero.
10. [G]
This command is used to request group data.
With the command, the user can identify which
input or output of a particular group is on.
Command Format: [GkUi]
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
Example:
If group 1 has DA Cards with output 1, 2 and 3
on, while group 2 has SW Cards with input 2 on: