Installation Instructions

- 4 - R1224DC16CBV Installation Guide
Rack Mechanical Drawing and Dimensions (H x W x D approximate):
Unit: 3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm).
Unit with Rack Brackets Attached: 5.21” x 19.125” x 8.5” (132.3mm x 486mm x 216mm)
3.26" (83mm)
8.5" (216mm)
17.625" (447.7mm)
1d1c1b1a
1d1c1b1a
2d2c2b2a3d3c3b3a4d4c4b4a
IEC 320 Connector
115VAC 60H.
1" (25.4mm)
19.125" (486mm)
5.21" (132.3mm)
LEDLEDLEDLED
Bottom View
Rear View
Front View
Fig. 3 Fig. 3a Fig. 3b
Fig. 3d
Fig. 3c
Illuminated master power disconnect circuit breaker:
OFF position - Switch not illuminated. Outputs not powered.
RESET (ON) position - Switch illuminated. Outputs powered.
Circuit breaker tripped - Switch not illuminated. Power LEDs on
faceplate are not illuminated. Outputs not powered.
To reset circuit breaker set power switch to the ON (RESET) position.