Installation Instructions

Overview:
These units convert a 115VAC or 230VAC, 50/60Hz input into a regulated 12VDC or 24VDC output up to 2.5A of con-
tinuous load current (see specifications).
SMP3CTX Series Power Supply Configuration Reference Chart:
Altronix
Model Number
Accessory
Power
Distribution
Module(s)
Number
of
Outputs
Fused
Outputs
PTC
Outputs
Individual
Output
Rating (A) Supervised
115VAC/
230VAC
Input
Current (A)
12VDC/
24VDC
Total Output
Current (A)
SMP3CTX
---- 1 ---- ---- 2.5A
----
0.65A/0.35A 2.5A
SMP3PMCTX
P
SMP3PMCTXX
SMP3PMP4
PD4
4
P
---- 2.5A
SMP3PMP4CB
PD4CB ----
P
2.5A
SMP3PMP8
PD8
8
P
---- 2.5A
SMP3PMP8CB
PD8CB ----
P
2.5A
SMP3PMP16
PD16W
16
P
---- 2.5A
SMP3PMP16CB
PD16WCB ----
P
2.5A
Specifications:
Power Supply Voltage Output Specifications:*
Output VDC Switch Position Max. Load DC
12VDC SW1 - ON (Fig. 1c, pg. 3) 2.5A
24VDC SW1 - OFF (Fig. 1c, pg. 3) 2.5A
*Specified at 25˚ C ambient.
Installation Instructions:
Wiring methods should be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local
codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 4).
Secure enclosure to earth ground.
SMP3CTX Series Installation Guide
Agency Listings:
CE European Conformity.
Input:
Input 115VAC, 50/60Hz, 0.65A or
230VAC, 50/60Hz, 0.35A.
Output:
12VDC or 24VDC selectable output.
2.5A supply current.
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Battery Backup:
Built-in charger for sealed lead acid or gel type batteries.
Maximum charge current 0.5A.
Zero voltage drop when switching over to battery backup.
Features:
Power ON/OFF switch.
Supervision (select models):
AC fail supervision (form “C” contacts).
Low battery supervision (form “C” contacts).
Visual Indicators:
AC input and DC output LED indicators.
Electrical:
Operating temperature: 0º C to 49º C ambient.
Mechanical:
Enclosure Dimensions (H x W x D approx.):
SMP3CTX, SMP3PMCTX, SMP3PMP4,
SMP3PMP4CB, SMP3PMP8, SMP3PMP8CB,
SMP3PMP16, SMP3PMP16CB:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
- Accommodates up to two (2) 12VDC/7AH batteries.
SMP3PMCTXX:
15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm)
- Accommodates up to two (2) 12VDC/12AH batteries.

Summary of content (4 pages)