Installation Guide

- 2 - T1MK Kits
Overview:
Altronix Trove Mercury kits are pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power
supply/charger and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to four (4) doors in a
single enclosure.
Configuration Chart:
Altronix
Model
Number
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Nominal DC
Output Voltage
Maximum
Supply Current
for Main and
Aux. Outputs
on Power
Supply board
and ACM4/
ACM4CB
Access Power
Controller’s
outputs (A)
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Fail-Safe/Fail-Secure
Outputs (auto-resettable)
Current Per
ACM4 Output (A)
Current Per
ACM4CB Output (A)
ACM4/ACM4CB Board
Input Fuse Rating
ACM4 Board
Output Fuse Rating
ACM4CB Board
Output PTC Rating
PDS8/PDS8CB Board
Input Fuse Rating
PDS8 Board
Output Fuse Rating
PDS8CB Board
Output PTC Rating
[DC] [Aux]
24VDC Output
Range (V)
24VDC Output
Range (V)
T1MK1F4
3.5
5A/
250V
7.5A/
32V
20.28-
26.4
20.28-
26.4
24VDC @ 3.6A 4 2.5
10A/
250V
3A/
250V
T1MK1F4D
3.5
5A/
250V
7.5A/
32V
20.28-
26.4
20.28-
26.4
24VDC @ 3.6A 4 2.0
10A/
250V
2.0A
T1MK1F4S
3.5
5A/
250V
7.5A/
32V
20.28-
26.4
20.28-
26.4
24VDC @ 3.6A 4 2.5
10A/
250V
3A/
250V
10A/
250V
3A/
250V
T1MK1F4SD
3.5
5A/
250V
7.5A/
32V
20.28-
26.4
20.28-
26.4
24VDC @ 3.6A 4 2.0
10A/
250V
2.0A
10A/
250V
2.0A
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two (2) keyholes in the enclosure. Install two upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure.
Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the
enclosure’s upper keyholes over the three upper screws. Install the two lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model T112 or equivalent) in desired location, opposite hinge.
Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Position Mercury access controller modules over corresponding spacers and depress onto
snap on spacers, Fig. 2, pg. 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow4NB,
and corresponding Sub-Assembly Installation Guide for ACM4(CB), PDS8(CB)
and VR6 for further installation instructions.
6. Mount backplane to enclosure with hardware.
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure