Installation Guide

- 2 - T3MK Kits
Overview:
Altronix Trove Mercury kits are pre-assembled and consist of Trove3M3 enclosure/backplane with factory installed Altronix power sup-
ply/charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a
single enclosure.
Configuration Chart:
Altronix
Model Number
Nominal DC Output Voltage
Maximum
Supply
Current for
Main and Aux.
Outputs on Power
Supply board
and ACM8(CB)
Access Power
Controller’s
outputs
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
120VAC 60Hz
Input Current (A)
Current Per
ACM8(CB) Output (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
ACM8(CB) Board
Input Fuse Rating
ACM8 Board
Output Fuse Rating
ACM8CB Board
Output PTC Rating
PD8UL Board
Output Fuse Rating
PD8ULCB Board
Output Fuse Rating
Power Supply 1 Power Supply 2
[DC] [Aux] [DC] [Aux]
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
T3MK75F16
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A
16 8 2.5
6.3A/250V
5A/250V
15A/
32V
10A/
250V
2.5A/
250V
3.5A/
250V
T3MK75F16D
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A
16 8 2.5
6.3A/250V
5A/250V
15A/
32V
10A/
250V
2A
2.5A
T3MK77F16
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4
24VDC @ 9.2A 16 9 2.5
6.3A/
250V
15A/
32V
10A/
250V
2.5A/
250V
3.5A/
250V
T3MK77F16D
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4
24VDC @ 9.2A 16 9 2.5
6.3A/
250V
15A/
32V
10A/
250V
2A
2.5A
Hardware and Accessories:
Two (2) tamper switches (Honeywell Model 112 or equivalent).
Cam lock.
Battery leads.
Mechanical:
16 Gauge grey enclosure with ample knockouts for convenient access.
• Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the
enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch
wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Mercury boards to backplane, refer to pg. 3, 4.
5. Refer to the corresponding eFlow Power Supply/Charger Installation Instructions
for eFlow104NB, eFlow102NB and Sub-Assembly Installation Instructions for
PD8UL(CB) and ACM8(CB) for further installation instructions.
6. Position Mercury access controller module over corresponding standoffs and depress onto
snap on standoffs (Fig. 2-3, pg. 3-4).
7. Mount backplane to enclosure with hardware.
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Fig. 1