Rack Mount Power Supplies Installation Guide Models Include: Vertiline3D - 12VDC @ 8 amp - Eight (8) PTC protected outputs Vertiline6D - 24VDC @ 8 amp - Eight (8) PTC protected outputs Rev. 051909 More than just power.
Overview: Altronix Vertiline Rack Mount Power Supplies provide eight (8) filtered and electronically regulated power outputs in a space saving 1U EIA 19” rack mount chassis. The units are available with either 12VDC or 24VDC power outputs. Vertiline Rack Mount Power Supplies are also available in sixteen (16) outputs. VertiLine Specifications: VertiLine6D: VertiLine3D: • Eight (8) 12VDC power outputs. • Eight (8) 24VDC power outputs.
10. The power LEDs on the faceplate for Outputs 1-8 will illuminate when AC power is present (Fig. 1a, pg. 4). Note: If any of the power LEDs are not illuminated the cause may be due to the following: a. AC mains fail. b. Illuminated master power disconnect circuit breaker is OFF or tripped. c. One (1) or more power output PTCs are tripped due to a short circuit or overload condition. To reset the PTC: 1. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1d, pg. 4). 2.
-4- Vertiline3D/VertiLine6D 1e Removable Terminal Block. 1d IEC 320 Connector: 115VAC 60Hz (grounded line cord included). 1c Illuminated master power disconnect circuit breaker (switch): • OFF position Circuit breaker tripped Switch not illuminated. • RESET (ON) position Switch illuminated. 1b Power Outputs: 12VDC or 24VDC. 1a LED(s) 1-8: Power LED indicators. 1d Vertiline3D and Vertiline6D (rear) 1a Vertiline3D and Vertiline6D (front) Fig.
Vertiline3D/VertiLine6D -5- Fig.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Chassis Mounting Options: Rack Mount Installation 1- Remove factory installed screws from both sides of rack chassis (Fig. 3a). 2- Attach mounting brackets (A) on the left and right side of rack chassis using the two (2) flat head screws (B) (included) (Fig. 3b). 3- Install unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 3c). Fig. 3 Fig. 3b Fig. 3a Top Fig.
Notes: Altronix is not responsible for any typographical errors. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.