Replace one wall jamb [B] and attach to wall
with two #8 x 1 1/2" truss head screws [D] inserted
through the top and bottom holes. Slip a nylon
spacer [E] over a #8 x 1 1/2" truss head screw and
install in the center hole of the wall jamb. Check
jamb for plumb and tighten screws.
NOTE: Do not overtighten the jamb screws.
NOTE: Obscure glass doors should be
installed with the rough surface of the glass to the
exterior of the unit. Deco or etched glass doors
should be installed with the patterned surface to
the inside.
On doors with obscure or etched glass, there is an
interior and exterior glazed door panel [G] as
determined by the position of the top bearing fin.
Door panels with clear glass are interchangeable.
Attach the four nylon roller bearings [H] to the
door panels as shown, using #8-32 x 3/8" hex head
screws [J] centered in the outside slots in the top
bearing fins.
5
This bath enclosure is equipped with safety
tee-lock wall jambs. When properly installed, the
header is permanently locked to the wall jambs
and cannot be accidentally dislodged.
Measure the wall-to-wall opening at the top of the
wall jambs [B] and cut the header [F] 1/16" short
of this dimension. Check the header for fit.
Slide the safety tee-lock of the unmounted wall
jamb [B] into the end of the header. The header is
reversible so that either face may be turned to the
exterior of the unit. Holding the header at an
angle, engage the other end onto the mounted wall
jamb. Pivot the header into place, then slide the
loose wall jamb to the wall and press into position
on the tub track. Attach the jamb to the wall per
instructions in Step #4.