Operation (8500, 10,000 & AWW Units with on/off toggle switch)
1. Make sure that the unit is plugged into a grounded outflow (120 Volt, 60 Hz).
2. For optimum performance, the HEPA system should operate when the indoor air handler/furnace blower is on.
3. Turn the unit on by rotating the variable speed dial clockwise. The unit starts in High speed, turn all the way
clockwise for low speed.
For units with a n on/off toggle switch, press the switch to the ‘on’ (1) position.
4. To turn the unit off, rotate the variable speed dial counter-clockwise until you feel or hear it click into the ‘off’
position.
For units with an on/off toggle switch, press the switch to the ‘off’ (0) position.
Operation (AWW-350 & AWW-675)
1. Make sure that the unit is plugged into a grounded power source (120 Volt, 60 Hz).
2. For optimum performance, the HEPA system should operate with the indoor air handler/furnace blower on.
3. Turn the unit on by pressing the on/off button and the green power light will illuminate.
For units with a n on/off toggle switch, press the switch to the ‘on’ (1) position.
4. To turn the unit off, press the on/off button and the power indicator light will go out.
For units with an on/off toggle switch, press the switch to the ‘off’ (0) position.
Filter Light Indicators
Your HEPA system is equipped with an electronic filter timer. This timer monitors the life expectancy of each fil-
ter in the unit.
By default, the Pre-Filter, HEPA Filter and VOC Blanket lights will turn on when the unit is powered on.
5. If you have upgraded your VOC Blanket to a VOC Canister, you must activate the corresponding timer.
Press and hold the VOC Canister button until the light comes on. The VOC Blanket light will automatically
go off. The control panel will now monitor the life expectancy of the VOC Canister.
6. If you are switching your VOC Canister to a VOC Blanket, you must activate the corresponding timer. Press
and hold the VOC Blanket button until the light comes on. The VOC Canister light will automatically go off.
The control panel will now monitor the life expectancy of the VOC Blanket.
When a filter indicator light flashes, it is time to check and replace that filter.
7. Turn the unit off and see instructions for “filter removal” on pg. 14. to determine if filter replacement is need-
ed. See ‘Maintenance” on next page.
8. Once the filters have been checked or replaced, turn the unit back on and reset the control panel. To reset,
press and hold the flashing filter button until the light is constant.