Accessories Catalog
CT-DPTAC www.amana-ptac.com 3
sTandard FeaTures (conT.)
Our condensate dispersion system removes condensate from indoor cooling operaon
by throwing water directly on to the outdoor coil for rapid evaporaon and increased cooling eciencies. The slinger
ring on the new, enhanced fan draws water up and into the fan blades. This water is then atomized and evaporated into
the atmosphere through the condenser. Increased surface area from the coil allows more water to be evaporated on the
sides of the coils and helps to minimize condensate run-o.
Each unit comes equipped with the DigiSmart™ control and energy management soware. With
Digi-Smart™ using the oponal RF antennae, all units can be wirelessly connected to a central hub for enhanced energy
savings and diagnoscs. Amana brand PTACs also have a low-voltage interface capability with a eld-supplied front-desk
ON/OFF switch. (See Page 4.)
When the unit senses temperatures of 40°F or below, the unit acvates the fan motor and
either the electric resistance heater or the hydronic heater.
No complex controls to confuse your guests and create phone calls for your manager. Controls are
easy to read, understand, and acvate. Our new 7-buon control panel provided guests with complete control of the unit
for their in-room comfort while maintaining overall energy eciency.
The main components are easily serviced and there is no guessing to
determine the problem with our easy-to-read diagnoscs.
Our Stonewood room front strikes the balance between aracve styling and praccal design.
Disncve contours and a modern appearance enhance the character of even the most luxurious room, while the sleek
7⅝” depth maximizes usable space for your guests.
When the DigiSmart™ wireless remote thermostat is set up, both the remote thermostat
and unit control panel connue to control the unit, providing exibility and home-like system control. Installaon re-
quires no more than pressing two buons. No need to run wires or make electrical connecons.
Guests enjoy ulmate comfort with consistent climate control. When the eld-installed
thermistor (RTS03) is used, the unit-mounted thermostat is overridden to allow more accurate, internal wall-sensing of
room ambient temperature.
Heat pump models will operate in the heang mode down to as low as 24°F outdoor
ambient temperature.
The unit can be installed ush to a nished oor, if desired. (Some accessories do not have zero
clearance).
The fan connues to run 30 seconds aer the compressor has stopped in either cooling or heat
pump mode and aer electric heat has been turned o. This improves eciency by dispersing the condioned air on the
coils into the room.
This feature helps prolong the life of the compressor by prevenng short-cycling. When the com-
pres-sor is switched from O to On because room temperature has risen or fallen below the specied limit, it will remain
on for at least 4 minutes. If the temperature set-point is changed during this 4 minutes, the lock-in feature is overridden.
No more “my unit is not heang” complaints during the middle of the night. Heat pump
units will automacally switch over to electric resistance heat if the heat pump compressor system fails or if the heang
load is greater than the unit capacity.
Take advantage of each unit’s dual opons — select connuous fan operaon or cycle the fan ON
and OFF with the thermostat. Our new 7-buon design allows guests to select fan performance while allowing the owner
to have the unit revert to the desired program of connuous fan or cycle with condioning.
The venlaon control lever is hidden from the occupant's view to allow you to manage
venlaon requirements.
Protects the unit from high pressure and damage to the unit, helping to ensure long unit life.