INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS ZECL-26-2923-BG ZECL-30-3226-BG ZECL-33-3624-BG ZECL-39-4134-BG ZECL-2939-BG INSERT-26-3825-BG INSERT-30-4026-BG INSERT-33-4230-BG ZECL-26-2923-FLUSHMT-BG ZECL-30-3226-FLUSHMT-BG SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
TABLE OF CONTENTS Please read and carefully follow all of the instruction found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product. IMPORTANT INSTRUCTIONS....................................................................................................................... 3 UNPACKING AND TESTING APPLIANCE ...........................
IMPORTANT INSTRUCTIONS 1. Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and rear as well. 3. Always unplug heater when it’s not in use. 4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way. 5. Do not use the heater outdoors. 6.
UNPACKING AND TESTING APPLIANCE Carefully remove the appliance from the box. Remove the packing screws from both sides of the fireplace. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the power supply cord into a conveniently located 120 Volt grounded outlet. Test all aspects of its operation (manual switches, remote and heater) to make sure all components operate correctly.
3. A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location. Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses to blow. CLEARANCES WHTN BUILT-IN The fireplace may be placed within a framed enclosure that is level, dry and capable of supporting the weight of the appliance and front glass. It may be placed directly on wood or a non-combustible surface(not on linoleum or carpet).
ZECL-26-2923-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU Built-in Appliance This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. 120V AC 60Hz 1500W Max 25W 19W 25 1/4” or 64.2 cm 22 3/8” or 56.
ZECL-30-3226-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 29 3/8” or 74.6 cm 24 7/8” or 63.
ZECL-33-3624-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 31 3/4” or 120.6 cm 22 3/8” or 53.
ZECL-39-4134-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 37 5/8” or 180.4 cm 31 7/8” or 53.
ZECL-2939-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 24 1/4” or 180.4 cm 37 3/4” or 53.
INSERT-26-3825-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 25 1/4” or 64.2 cm 16 7/8” or 42.
INSERT-30-4026-BG This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 29 1/2” or 74.6 cm 19 1/4” or 48.8 cm 8 3/4” or 22.2 cm 74.8lbs or 34kg Left side 70 7/8” or 180 cm 31 3/8”× 19 7/8“ or 79.7 cm× 50.5 cm 4800 2634" [682.0mm] 40" [1015.2mm] 291 2" [746.
INSERT-33-4230-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 31 3/4” or 120.6 cm 22 3/8” or 53.
ZECL-26-2923-FLUSHMT-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 25 1/4” or 64.
ZECL-30-3226-FLUSHMT-BG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 29 3/8” or 74.
INSTALLATION OVERVIEW – MASONRY FIREPLACES Cover plate is required if chimney does not have suitable rain cap. one Silic There must be a minimum 1" gap between the wall and the glass surround. Do not block this gap with finishing materials or trim 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method).
INSTALLATION OVERVIEW –ZERO-CLEARANCE (METAL) FIREPLACES Cover plate is required if chimney does not have suitable rain cap. There must be a minimum 1" gap between the wall and the glass surround. Do not block this gap with finishing materials or trim one Silic The log shelf, screen, and doors (if present) must be removed. 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration.
HARD- WIRE INSTALLATION Turn off the appliance completely and let cool before servicing. Only a qualified service person should service and repair this electric appliance. If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the appliance directly to the household wiring. This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the absence of local codes, use the current CSA C22.
MEDIA OPTIONS The fireplace shipped with an ember log set that is pre-installed. Consumers have their choice of decorative media should they wish to install it. Log set Installing the decorative media Log set Pour the decorative media into the tray. Feel free to use any combination of fire glass media that you find most appealing. Put back the front glass after you finish install the fire glass.
OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. The main power ON/OFF switch in position O, the fireplace is OFF. 2. When main power ON/OFF switch is at position I, the fireplace is ready to use. 3. Press the button repeatedly to set the heater to desired heat setting. The heater indicator LED will glow which shows the current heater settings.
REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and main power switch located on the bottom left hand side is at position I. When operating the remote make sure you point the remote to the centre of the fireplace and make sure each time you press the button the buzzer inside the unit will beep once. It takes some time for the receiver to respond to the transmitter. Do not PRESS the buttons more than once within two seconds for correct operation.
INSTALLING WALL THERMOSTAT WALL THERMOSTAT WIRING DIAGRAMS NOTE: THE WALL THERMOSTAT WILL WOKING WHEN THE HEATER ON TEMP. SETTING.PLEASE REEFER TO THE MANUAL CONTROL AND THE REMOTE CONTROL. Wire the wall thermostat prior to installing the fireplace. WALL THERMOSTAT WIRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2. Remove cover plate located on the left up side of appliance. 3.
REPLACEMENT PARTS PART NUMBER NO QTY.
EXPLODED VIEW 25
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE Dim or no flame Flame LED’s are burnt out Ember bed is not glowing or dimming Appliance turns off and will not turn on Appliance will not come on when switch is flipped to ON SOLUTION Inspect the LED’s and replace them if necessary. Back black cloth is falling off Change a new flicker and back black and roll the flicker cloth. Ember LED’s are burnt out Inspect the ember bed LED’s and replace them if necessary.
SERVICE HISTORY This heater must be serviced annually depending on usage.