HOME AIR TREATMENT CENTRE PLDA 19EH 25EH GB Instruction manual
GB ELECTRICAL CONNECTION - UK ONLY For your safety please read the following information. Warning: This appliance must be earthed. This appliance operates from a 3 pin 13 amp plug. The voltage rating is 230 volts and should be protected by a 13 amp fuse either in the plug or distribution board. The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse. Should the fuse require replacement, it must be replaced with a fuse rated at 13 amp and approved to BS1362.
GB THANK YOU ! Thank you for choosing this innovative Amcor product. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use it, you should carefully read these instructions to maximise this product’s performance.
GB IMPORTANT! • The unit is designed for indoor operation. • Rating: This unit must be connected to a 220-240 V / 50 Hz earthed outlet. • The installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the electrical installation, have it checked and if necessary modified by a qualified electrician. • Unplug when not in use. Do not unplug by pulling the cord. • Do not operate this product with wet hands. • Keep out of the reach of children.
GB HOW IT WORKS Your AMCOR dehumidifier draws air through a multi stage high efficiency washable filter onto a refrigerated cold coil. As the air in the room passes over the cold surface, moisture condenses and collects into a removable water tank. The drier, slightly warmer air is then expelled through the air outlet located behind the control panel of the unit into the room. When the water tank is full, a micro-switch automatically stops the unit and an indicator light signals the need to empty the tank.
GB PLACEMENT Your AMCOR dehumidifier will begin to protect your home from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture travels throughout your home, in the same way that cooking smells spread to every room in the house. For this reason, the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home. A warm hallway or landing is an excellent position for your dehumidifier.
GB AIR PURIFYING Your dehumidifier is fitted with a high definition multi-stage air purification system. Stage one A preliminary washable dust filter. The filter absorbs irritating odours such as that from mould, stale cigar smoke, or vehicle fumes so they are not recirculated into the cleaner air. Stage two An activated carbon odour absorbent filter. Stage three (optional) An optional 3M HAF filter or a TiO2 filter for purifying the air from bacteria.
GB CONTROLS 13 1 12 2 11 3 10 4 9 8 7 6 5 Humidity set mode. High fan speed. Low fan speed. Dehumidification – compressor runs. Timer set is on. Setting the timer ON. Setting the timer OFF. Real time indication and timer setting(s). Indication of room relative humidity and temperature. In all units – to confirm or cancel the timer press the set button - it indicates the status as follows: – cancels the ON timer. – cancels the OFF timer. – confirms the 01 timer. – confirms the 02 timer. 10.
GB Setting the time The real time is shown on the clock, the 4 digits at the bottom of the LCD. The moment the unit is connected to the electricity, the default time 12:00 is shown. Push the SET BUTTON for 2 seconds, the 2 left digits will blink, adjust the hour by pressing the or button repeatedly. To set the minutes push the SET BUTTON again for 2 seconds. The 2 right digits blink. Press the or button repeatedly to adjust the minutes. Push the SET BUTTON again and the real time is set.
GB When the unit is OFF. Follow the same procedure as above for the ON and if required continue to the OFF setting. Cancelling the timer In order to cancel the timer setting(s), push the TIMER BUTTON. UV light (optional) Normally the blue UV light will be ON whenever the unit is connected to the electricity. In order to turn the blue UV light off, push the UV BUTTON, the UV light will go OFF and the UV icon on the LCD will disappear. Pushing the UV BUTTON again will light the UV light.
GB MAINTENANCE Always unplug the unit from the mains before carrying out any maintenance or cleaning the unit. Cleaning the body Use only a soft cloth to wipe the unit clean. Do not use volatile chemicals, petrol, detergents, chemically treated cloths or other harmful cleansing solutions. These could all possibly damage the cabinet. Cleaning the washable air filter This dehumidifier is equipped with a washable filter.
GB EMPTYING THE WATER TANK When the water tank is full, the unit will switch off and beep 10 times, the blue led icon on the LCD will come on.
GB CONTINUOUS DRAINAGE (OPTIONAL) For the continuous drainage please refer to the following instructions and pictures : 1. Cut out the hole for the drainage tube on the back of the unit. There are 4 tiny strips holding the cover in the hole, just cut them and the cover will come out. 2. Push the supplied drain tube through the hole in the back of the unit and fix it on to the plastic drain tube. 3. The water tank have to remain in place also in the continuous drainage. 4.
GB TROUBLE SHOOTING Never try to repair or dismantle the unit yourself. Before calling for assistance please check the points below. The unit doesn’t run. Is the machine plugged in? Is the mains power supply on? Is the water tank full indicator on? (If so, the water tank is full or it isn’t positioned properly). The unit seems to Are too many windows or doors open? extract little water.