THANK YOU Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximise this product’s performance and the proper operation. The appearance of the unit that you purchased may differ from the one described in the manual.
WARNING • Never operate this appliance if it has a damaged cord. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. • Never operate with wet hands. • Do not attach, hang or stack anything onto the air conditioner.
HOW IT WORKS The compressor (6) in the exterior unit compresses the refrigerant into a high-temperature, high-pressure gas. When this gas flows along the cooling fins of the condenser (7), heat is exuded and the gas condenses into a liquid, which is led to the evaporator (1) in the interior unit. The liquid expands into a gas at a low temperature and low pressure.
REMOTE CONTROL Note: The symbols on your AHW 164 remote control may differ from the ones used in this manual. LCD display: Auto mode Sleep Cool Dehumidify Fan mode Temperature Fan mode Fan speed indicator Auto (fan, vane control) Airflow direction Clock Order of timer operation Timer Timer on Timer off Temperature set Using the remote control The remote control signal has a range of up to 8 m. Point the remote control at the receiver in the interior unit.
OPERATION General • Turn the appliance on with the ON/OFF button . This activates the most recent setting. turns the appliance off; the type of operation set at • The ON/OFF button that time is stored in the memory. • The MODE button cycles through the various modes in this order: auto , cool , dehumidify , fan . • The desired temperature is set with the up and/or down -button, within the limits of the thermostat: 64 °F – 86 °F (18 °C – 30 °C).
Dehumidify 1. Press the MODE button until the dehumidify symbol appears. 2. Set the desired temperature with the up and/or down -button. 3. The FAN SPEED button does not work in dehumidify mode. The fan speed will always be low in this mode. Fan mode 1. Press the MODE button until the fan symbol appears. 2. Set the desired temperature with the up and/or down -button. 3. Use the FAN SPEED button to set the fan speed. Sleep mode 1.
Air flow direction Fins (vertical vanes) Press the IN FLAP button to let the fins turn left/right for an air flow direction that is comfortable to you. Vanes Press the OUT FLAP button to change the horizontal direction of the air flow, the vanes take these positions in sequence: . Usually the auto position works fine. Positions (1) and (2) are recommended for cool and dehumidify mode.
Emergency start In the event of a problem or missing remote control, the air conditioner can be operated using the emergency button under the panel in the interior unit. Open the front panel and press the button to switch on (in the mode last set) or to switch off. FILTERS Turn the appliance off and disconnect the power. B A A To open: at the A recesses, pull the front part up. The front part will stay horizontal (turn up 60 °).
CLEANING Turn the appliance off and disconnect the power. Interior unit Check that the condensation outlet drains properly. Dust regularly with a dry cloth or slightly damp paper towel. Never use chemicals or solvents. Never spray a liquid in or over the appliance. Exterior unit Remove dirt and keep the air intake and exhaust openings free of leaves, etc. Cleaning with chemicals may cause damage.
INSTALLATION GUIDELINES Which Air Conditioner is best suited for your room? Many windows Much sunshine (conservatory) Size of the room (floor area) 125 BTU /f t 2.h 115 ft2 225 ft2 Less windows Less sunshine 400 ft2 35 B TU /ft 2 .h 575 ft2 Cooling capacity BTU/h 8000 11000 14000 17000 20000 The most suitable air conditioner depends on the surface area, sun location, window area, presence of heat sources (lamps, appliances, number of people etc.).
Point of attention for the installation of electric components • HACR type breaker should be utilized along with proper installation. • Be sure to use the applicable voltage and cables or wires for the unit to be installed, before making the connections. • Read the prompts at the terminal board for wiring. Make sure the wiring is done correctly. • Pay attention to the poles of the signal terminal and connect the terminals to match the identification numbers.
TROUBLE SHOOTING Cases requiring immediate contact with your dealer: • breaker or fuse breaks off often. • malfunction of TV, radio or similar devices. • switch does not result in sure performance • abnormal noise during operation. • if a faulty operation does not disappear after restart (after having waited for 3 minutes). Check the following before requesting after sales service from your dealer: The air conditioner does Is the unit connected to a power supply? not operate at all.
RATING LABELS INDOOR UNIT OUTDOOR UNIT AHW 164 See barcode 230 V 60 Hz 1 Ph AHW 164 See barcode 230 V 60 Hz 1 Ph Model Serial number Power supply Model Serial number Power supply 1.2 kW 5.1 kW 18000 BTU/h 13 BTU/h W IP 20 Cooling capacity SEER Protection class R410A 64-86 oF 18-30 oC 1040 m3/h 36700 cu.ft/h Refrigerant Thermostatic range Airflow up to 40 L/day 84 pts/day ~44 - 50 dB(A) 18 kg / 40 lb Dehumification Noise level Weight net Caution: 1.
NOTES 15
Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 88141 Email: amcoruk@amcorgroup.com USA Amcor Inc.