Instruction manual

TROUBLE SHOOTING
7
If the product is used according to this manual you should enjoy trouble free use.
In case of difficulty please check the following points and refer to the Amcor Help line
should you need further assistance?
Problem Check Remedy
Product does not start Is the “power” light on? Make sure the unit is plugged in to a
live mains socket.
Is the “water full” light on? Make sure the container is empty of
water and fitted properly in position.
Make sure the float in the water
container is attached and not broken
Water is leaking
outside of the water
tank in continuous
drainage mode?
Is the continuous drainage
funnel selector properly
positioned?
Ensure that the drainage funnel
selector is pulled forward and clicked
into position.
To return the unit to water tank use,
push the funnel selector back into
the unit until it clicks and re-insert the
stopper.
Check there are no blockages to the
flow out of the funnel.
Has the unit been running
in cold temperatures under
5ºC?
Switch off for 2 hours to defrost in
an area where a water leak will not
cause damage and only run the unit
in a heated room above 5ºC
Has the container been
removed for emptying
straight after the unit was
running?
Wait a few minutes to allow possible
ice and condensation within the
unit to flow into the container after
switching off the unit.
Reduced water
extraction
Is the humidity knob 3 turned
too far anticlockwise turning
the compressor off when the
humidity is still higher than
required?
Turn the humidistat knob (3 on
controls page) clockwise to a make
the dehumidifier extract water down
to a lower relative humidity or fully
clockwise to the continuous setting.
Is the air already relatively
dry?
Water extraction rate is reduced
when the humidity level is reduced
e.g. when the air temperature is low.
Is the unit running in a cold
room?
Generally the colder the
air the less moisture will be
removed.
Ensure that the unit is operating in a
heated room above 5ºC. Switch off
for 2 hours to defrost and restart with
the heater switched on.
Are the filters blocked? Washable air filter may need
cleaning.
Activated carbon filter (where fitted)
may need replacing.
Not collecting water Is the “water full” light on? Make sure the container is empty of
water and fitted properly in position.