Instruction manual

GB
1
CONTINUOUS DRAINAGE (OPTIONAL)
Never try to repair or dismantle the unit yourself. Before calling for assistance please check the points
below.
The unit doesn’t run. Is the machine plugged in?
Is the mains power supply on?
Is the water tank full indicator on? (If so, the water tank is full or it isn’t
positioned properly).
The unit seems to
extract little water.
Are too many windows or doors open?
Is there something in the room producing lots of heat?
Is the room cold – the colder the air the less moisture the unit will extract.
Is the lter dirty?
Is the room humidity already quite low?
The unit seems to do
nothing.
Is the lter dirty?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
Is the room temperature below 5 °C? The fan may run without the
compressor.
Too noisy. Is the machine positioned unevenly so as to create vibration?
Is the oor underneath the unit uneven or loose tting?
Is there any foreign body interfering with the unit?
The unit’s fan doesn’t
seem to be revolving.
Is the lter blocked?
Is there any foreign body interfering with the unit?
The continuous
drainage is not working.
Does the hose have a downward slope throughout its entire length?
Is there a kink or sharp bend in the hose?
Model PLDA 19E PLDA 19EH PLDA 25E PLDA 25EH
Mains 220 - 240 V / 50 Hz
Power consumption
(at 32 °C, RH 90 %)
W 300 390
Heater (PTC type at 20˚C) W - 470 - 470
Moisture removal
(at 32 °C, RH 90 %)
L/24h 19 25
Refrigerant R-134A
Refrigerant load g 155 200
Working temperature °C 5 - 35
Dimensions (W x D x H) cm 42 x 24 x 60
Net weight kg 14.5 15
Due to our continuous R+D program, specications may change without prior notice.
For current specications please refer to the rating label on your machine.
TROUBLE SHOOTING