Specifications

Intellex IP
74 Intellex®
10 Enter the following Network Information parameters
Server Type — this should be set to ADEIP4 for the IP Encoder and ADSDUIH for the
IPSDU8
Address — this is the IP address of the device
Port — this should be set 5001 for both the 4 Channel IP Encoder and the IPSDU8.
11 Enter the following Network Information parameters:
Username — this must be an existing Username configured on the IP device
Password — this must be the existing Password configured on the device for the above
Username.
12 Enter the following Video Stream parameters for each required Video Stream:
Name — a name for the Camera providing the video stream
Assignment — the Intellex IP camera number to use for the video stream assignment on the
Intellex IP display
Resolution — can be set for 1CIF, 2CIF or 4CIF
Quality — can be set for Extended Record, Normal or Super
Sensitivity — can be set for Normal or High
Maximum Rate — measured in Images Per Second (IPS), maximum value is 30
Enable Bandwidth Limit — can be set to On or Off
Bandwidth Limit — only applicable when Enable Bandwidth Limit is set to On. Meaasured in
KB/sec, with a range of 30 KB/sec to 400 KB/sec.
13 Select OK to confirm the settings. The system will return to the IP Sources screen with a new
entry added for the configured device. The device will be listed as an AD 4 Channel or IPSDU8.
Stream 2 applies to the
IP Encoder only and not
the IPSDU8.