Operating instructions

WARNING
Do
not fill
LP
gas containers to more than 80% capac-
ity.
Overfilling can result
in
uncontrolled gas flow which
can cause fire and
explosion. A properly filled con-
tainer holds about 80% of its volume
as
liquid.
WARNING
Turn off LP gas main valve before filling
LP
gas tank
or entering an
LP gas bulk plant or motor fuel service
station. Turn off
all pilot lights and appliances individ-
ually
before refueling of motor fuel tanks and/or
LP
gas containers. When not individually turned off, auto-
matic ignition appliances may continue
to
spark when
LP gas is turned off at the container.
LP GAS SYSTEM CHECK
Always have the system checked
by
a profes-
sional any time you detect a garlic/rotten egg
like odor or
heat·
a sustained hiss when you turn
the
LP gas on.
LP GAS
LEAK
DETECTOR/ALARM
A permanently installed LP gas leak detector/
alarm is located near the floor. The unit contains
an
alarm that will sound alerting you
to
the
presence
of
low levels
of
potentially dangerous
LP gas that may have accumulated.
The detector/alarm unit is powered by the
12-
volt DC system in your motor home. A green
light on the detector/alarm front panel indicates
that the detector/alarm has power.
Test the leak detector/alarm each time the motor
home is relocated and set up for use. Detailed
information for the leak detector/alarm can be
found in the
OWller's Illformation Package.
Testing Procedure:
I. Hold a butane-fueled pocket lighter near
the sensor.
2.
Open the lighter valve without striking the
flame.
3.
The leak detector/alarm should respond
within a few seconds.
IlP
Gas
System
4. Press the silence button
to
reset the alarm.
5.
Lightly fan the area around the detector/
alarm
to
insure complete dispersion of the
gas from the lighter, and
to
prevent
another sounding of the alarm.
6.
A silence button allows you
to
temporarily
quiet the alarm for
60 seconds after it has
been set off or after testing.
7.
If
the alarm does not sound during a test or
if
the green indicator light is not visible,
see your dealer or an authorized Fleetwood
Service Center. There are no batteries or
user serviceable parts inside the unit.
AJ
WARNING I
The LP gas leak detector/alarm will not function if
both battery disconnects are
OFF.
.II
NOTE
I
The
detector/alarm draws enough current to dis-
charge your battery. Remember
to
turn
off
the chas-
sis and house battery disconnects
if
you are not using
your motor home.
LIGHTING LP GAS APPLIANCES
Detailed operating information for the LP gas
appliances can
be
found in your Owner's
Information Package. Please read and follow
these instructions.
Air trapped in the gas lines may delay the initial
lighting
of
any appliance.
It
could take several
seconds or minutes for the gas
to
reach the
appliance.
To
purge some of the air from the gas
system, first light a burner on the range. The
other appliances will then light more quickly.
The first time the furnace or oven is operated,
paints and oils used in its manufacture may
gen-
erate some smoke and fumes.
If
this occurs,
open doors and windows
to
air out the motor
home. These materials should burn off after the
first
IS
to
20 minutes
of
appliance operation.
Always follow the appliance manufacturer's
lighting, operating and maintenance instructions.
09-3