Operator`s manual

SECTION 10. MAINTENANCE AND SERVICING
Form 169006 150 Revision D
C
10.6 HYDRAULICS
The CA20 Combine Adapter’s hydraulic system
provides oil for the header draper and knife drives
as well as the adapter feed draper.
Reel hydraulics are provided by the combine.
10.6.1 Reservoir
The adapter frame is used as a reservoir. Refer
to Section 10.3.4 Recommended Fluids and
Lubricants for proper oil.
10.6.1.1 Oil Level
Check oil level every 25 hours at sights (A) and
(B) with cutterbar just touching ground. Check
when oil is cold, and with center-link retracted.
Nominal - Normal Terrain:
Maintain level so
lower sight (A) is full, and upper sight (B) is
empty.
Maximum - Hilly Terrain:
Maintain level so
sight (A) is full, and sight (B) is up to one-half
filled.
Minimum - Level Ground
: For slopes of
6° or less, oil level may be kept slightly lower
if desired. Maintain level so sight (A) is
one-half filled or higher.
NOTE
When ambient temperatures are above
95°F (35°C), to prevent overflow at
breather under operating temperatures,
it may be necessary to lower oil level
slightly.
10.6.1.2 Adding Hydraulic Oil
CAUTION
Stop engine, and remove key from ignition
before leaving Operator's seat for any reason.
A child or even a pet could engage an idling
machine.
a. Turn filler cap (C) counter clockwise until loose,
and remove cap.
b. Add warm (room temperature) SAE 15W-40 oil to
required level. Refer to Section 10.3.4
Recommended Fluids and Lubricants for proper
oil.
IMPORTANT
Warm (room temperature) oil will flow
through the screen better than cold oil.
DO NOT
REMOVE THE SCREEN.
c. Re-install filler cap. Hand-tighten.
A
B
B
A