Operator`s manual

SECTION 7.6 CAT LEXION 400, 500 SERIES
Form 169006 52 Revision D
f. Disconnect hydraulics/electrical from adapter as
follows:
Lexion 500 Detachment
1. Unscrew knob (F) on coupler (G) to release
coupler from adapter.
2. Remove cover (H) from combine receptacle.
3. Locate coupler (G) onto combine receptacle,
and turn knob (F) to secure coupler to
receptacle.
4. Place cover (H) on adapter receptacle.
5. Proceed to step g. on next page.
Lexion 400 Detachment
1. Disconnect electrical harness from adapter.
2. Disconnect hydraulic hoses from adapter
connectors (L) and (M). Locate hoses (J)
and (K) on combine as shown, and
re-connect.
3. Unscrew knob on coupler to release coupler
from adapter receptacle (N).
4. Remove cover (O) from combine receptacle.
(continued next page)
H
H
F
G
F
G
M
L
N
K
J
O