Technical information

INSTALLATION
17
B.4. Install The Thermostat Bulb
Remove the evaporator filter side trim that supports the probes to access the back of evaporation frame, see DRAWING
B.3.1., page 10.
Install the thermostat bulb on the coil assembly frame as close as possible to the defrost heaters, but not closer than 5”,
see PHOTO B.4.1. Secure the bulb with cable ties to minimize risk of breakage of the capillary tube caused by vibration.
PHOTO B.4.1