Power Distribution Unit (PDU) AP7620 AP7621 AP7622 AP7626 User’s Manual ®
This manual is available in English on the enclosed CD. ❖❖❖ Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. ❖❖❖ Este manual está disponible en español en el CD-ROM adjunto. ❖❖❖ Ce manuel est disponible en français sur le CD-ROM ci-inclus. ❖❖❖ Questo manuale è disponibile in italiano nel CD-ROM allegato.
Contents Product Descriptions and Safety Information . . . . . 1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Downloading the Latest Firmware Revision. . . . . 17 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Warranty and Service . . . . . . . . . . . . . . . . . . . . . 22 Life-Support Policy . . . . . . . .
Product Descriptions and Safety Information Features of single-branch PDU models This manual explains how to install and use the following Rack-mount PDUs: PDU Voltage Number of Outlets Outlet Type AP7620 100–120 VAC 24 NEMA 5-20R AP7622 200–240 VAC 6 NEMA L6-20R 21 outlets of type AP7621 AP7626 200–240 VAC 25 IEC 320 C13 4 outlets of type IEC 320 C19 All the PDUs distribute input power from a single source to the PDU outlets for use by connected equipment and provide current-sensing to gua
Product Descriptions and Safety Information 120V PDU ➊ ➋ ➌ ➍ ➎ ➏ ➐ ! Rack-mount PDU (AP7620) " Display interface # NEMA 5-20R outlets (24) $ Cord retainer holes % NEMA L5-20 power cord & Serial cable ' Cord retainer 2 PDU: User’s Manual
Product Descriptions and Safety Information 208V PDU ➊ ➋ ➌ ➍ ➎ ! Rack-mount PDU (AP7622) " Display interface # NEMA L6-20R outlets (6) $ NEMA L6-20 power cord % Serial Cable PDU: User’s Manual 3
Product Descriptions and Safety Information 230V PDU with IEC 320 C20 power cord ➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑ ! Rack-mount PDU (AP7621) " IEC C13 outlets (21) # IEC C19 outlets (4) $ Display interface % Cord retainer holes & IEC 320 C20 power cord ' Serial cable ( Cord retainers (21 short, for use at the C13 outlets; 4 long, for use at the C19 outlets) 4 PDU: User’s Manual
Product Descriptions and Safety Information 230V PDU with NEMA L6-20 power cord ➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑ ! Rack-mount PDU (AP7626) " IEC C13 outlets (21) # IEC C19 outlets (4) $ Display interface % Cord retainer holes & NEMA L6-20 power cord ' Serial cable ( Cord retainers (21 short, for use at the C13 outlets; 4 long, for use at the C19 outlets) PDU: User’s Manual 5
Installation Mounting options You can install Rack-mount PDUs in one of two ways: using toolless mounting pegs or the mounting brackets. You mount the Rack-mount PDUs in the rear of the enclosure, in the channel directly behind the rear vertical mounting rails. Before you begin to install the Rack-mount PDUs, choose a location for them in the enclosure and decide on the mounting method.
Installation Toolless mounting 1. Decide where to mount the PDU and whether the power cord will be at the upper or lower end of the PDU. Caution Make sure that the power cord can reach an outlet easily, does not interfere with other equipment, and does not bend sharply. • In a PowerStruXure Type A system, you must mount the PDU so that its power cord is at the lower end.
Installation in the rear panel of the enclosure. 3. Push the PDU downward until it locks into position. .
Installation Bracketmounting You can order a rack-mount bracket kit from APC— AR8116BLK. The brackets attach to the Rack-mount PDU in two different directions, shown in the figures in step 1. Consider the orientation of the Rack-mount PDU in the enclosure before attaching the brackets. A recessed orientation allows the Rack-mount PDU to be mounted flush with the enclosure; a raised orientation allows you to route cables through the channel (see the figures in step 2). 1.
Installation brackets align with the holes. Tighten to secure the Rackmount PDU to the enclosure.
Operation Rack-mount PDU display interface ! " # $ Control Button To view the orientation of the LED display, press and hold the button for 5 seconds To change the orientation, hold the button for an additional 5 seconds until “AA” flashes and then changes orientation. To silence an alarm, press the button. " LED display Displays the current that is drawn by the load equipment. # Serial Port Provides the connection to access the internal configuration menus.
Configuration Using a serial port connection 0 1. Connect an available serial port of your computer to the serial port on the front panel of the PDU, using the supplied serial cable. 2. Run a terminal emulation program such as Windows® HyperTerminal. 3.
Configuration Access to menus When you log in as User, you can view information but cannot configure settings or enter data. When you log in as Administrator, you can view information, configure settings, and enter data. Any changes take effect immediately. To navigate the menus and their options, type the number of the selection you want, and press ENTER.
Configuration Main menu Menu Number Status Information option Option Name Access 1 Status Information Administrator and User 2 Metered Rack-Mount PDU Configuration Administrator and User 3 Device Data Administrator and User 4 Factory Data Administrator and User 5 Logout Administrator and User 6 System Management Administrator only (The menu is not displayed when you are logged on as User Choosing this option displays the following information about the PDU.
Configuration Device Data option Choosing this option displays the following information: Item Factory Data option Definition Product Name The name of the product, such as Rack-mount PDU. Product Location Where this PDU is located, such as Rack 4. Contact Information Whom to contact about this PDU. Log Timeout (mins) The number of minutes of inactivity that is permitted before you are logged out automatically. Admin Password The password required to log on as Administrator.
Configuration System Management option Choosing this option displays the following additional options Menu Number 1 16 Menu Name Restart RMPDU Definition Restart the PDU, using the parameters that are currently configured. 2 Restore Parameters and Restart Restart the PDU, using the default values for all parameters. 3 Firmware Download Prepare to download new firmware PDU: User’s Manual Access This menu option is displayed only if you are logged on as Administrator.
Downloading the Latest Firmware Revision How to download firmware to a Rack-mount PDU During firmware downloads, power will not be interrupted to the PDU outlets. Note 1. Go to www.apcc.com/tools/download/, and check to see if there is a version of firmware for your type of Rackmount PDU later than the version you are currently using. 2. Access the PDU internal menus through a serial port connection. See “Using a serial port connection” on page 12. 3. Log on to the Rack-mount PDU as an Administrator. 4.
Specifications AP7620 Electrical Specifications Input 100–120 V; 50–60 Hz; 16 A Output 100–120 V; 50–60 Hz; 16 A Physical Specifications Dimensions 1.75 × 3.5 × 48 in 4.5 × 8.9 × 121.9 cm Weight 11.75 lb 5.3 kg Shipping dimensions 3.75 × 5.0 × 60 in 9.5 × 12.7 × 152.4 cm Shipping weight 15.0 lb (6.
Specifications AP7621 Electrical Specifications Input 200–240 V; 50–60 Hz; 16 A Output 200–240 V; 50–60 Hz; 10 A (IEC C13 outlets); 16 A (IEC C19 outlets) Physical Specifications Dimensions 1.75 × 3.5 × 48 in 4.5 × 8.9 × 121.9 cm Weight 13.0 lb 5.9 kg Shipping dimensions 3.75 × 5.0 × 60 in 9.5 × 12.7 × 152.4 cm Shipping weight 14.5 lb (6.
Specifications AP7622 Electrical Specifications Input 200–240 V; 50–60 Hz; 16 A Output 200–240 V; 50–60 Hz; 16 A Physical Specifications Dimensions 1.75 × 3.5 × 48 in 4.5 × 8.9 × 121.9 cm Weight 14.0 lb 6.4 kg Shipping dimensions 3.75 × 5.0 × 60 in 9.5 × 12.7 × 152.4 cm Shipping weight 15.5 lb 7.
Specifications AP7626 Electrical Specifications Input 200–240 V; 50–60 Hz; 16 A Output 200–240 V; 50–60 Hz; 10 A (IEC C13 outlets); 16 A (IEC C19 outlets) Physical Specifications Dimensions 1.75 × 3.5 × 48 in 4.5 × 8.9 × 121.9 cm Weight 13.0 lb 5.9 kg Shipping dimensions 3.75 × 5.0 × 60 in 9.5 × 12.7 × 152.4 cm Shipping weight 14.5 lb (6.
Warranty and Service Limited warranty APC warrants the Power Distribution Unit to be free from Warranty limitations Except as provided herein, APC makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
replacement. 4. Pack the unit carefully. The warranty does not cover damage sustained in transit. Enclose a letter with your name, address, RMA number and daytime phone number; a copy of the sales receipt; and a check as payment, if applicable. 5. Mark the RMA number clearly on the outside of the shipping carton. 6. Ship by insured, prepaid carrier to the address provided by the Customer Support technician.
Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: • In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness. • In direct patient care.
Radio Frequency Interference Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
® APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer support requests. – www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. – www.apc.