Installation Guide

A60001
4 0611
UNDERMOUNT SINKS
Fabricator Template Preparation
The masonite template supplied by American Standard has been machined to the exact size and shape of the countertop
cut-out.
We recommend that this masonite template be used to create a female template from 1/2" plywood.
Use a router guide bushing and straight cutter bit to trace the masonite template onto 1/2" plywood, as indicated by
Figure 1, Part A, Template Preparation.
Sand the cut edge clean and smooth.
Part A Part B
Router Guide
Cutter Bit
Router Guide
Cutter Bit
Bushing O.D. Bushing O.D.
Recommended 3/8” 1/4” 1 9/64” 1/2”
Alternate 1/2” 1/4” 1” 1/4”
Part A
Part B
FIGURE 1
229062_Kindred_AMSD_DS_Farm_Undermount_A60001.qxd:Layout 1 7/8/11 11:36 AM Page 4