Installation Instructions

M965653 Rev. 1.8 (12/17)
5
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
AC VERSIONS (HARDWIRE / PLUG-IN);
Fig. 2
B
CAUTION
Disconnect AC power supply before opening CONTROL BOX.
NOTE: For AC installation, make power supply connection
before mounting CONTROL BOX (3) to wall.
1. Remove CONTROL BOX COVER (1). Feed the
EXTENSION CABLES (2) from the Faucet through the
top of ENCLOSURE (3). Fig. 2.
2a. Insert POWER CORD (8) through POWER SUPPLY
GROMMET (9) Fig. 2a.
3a. Insert POWER CORD (8) through side GROMMET (6) as
shown. Fig. 2a.
4a. Connect one of the 27" EXTENSION CABLES (2) to
SOLENOID CABLE (7) and the other to the SINGLE AC
ADAPTER (10). Connect POWER CORD (8) to SINGLE AC
ADAPTER (10) and install CONNECTOR LOCKING
DEVICE (16). Fig. 2a.
5a. Mount CONTROL BOX to wall. Replace CONTROL BOX
COVER (1). Tighten cover screws firmly.
6a. Plug AC POWER SUPPLY into wall outlet.
2b. Insert one end of the 10' EXTENSION (10a) through POWER
SUPPLY GROMMET (9). Fig. 2b.
3b. Insert 10' EXTENSION (10a) through side GROMMET (6) as
shown. Fig. 2b.
4b. Connect one of the 27" EXTENSION CABLES (2) to SOLENOID
CABLE (7) and the other to the 10' EXTENSION CABLE (10a).
Install CONNECTOR LOCKING DEVICE (16). Fig. 2b.
5b. Mount CONTROL BOX (2) to wall. Replace CONTROL BOX
COVER (1). Tighten cover screws firmly.
Contractor to supply ELECTRICAL BOX (12) and power to
POWER SUPPLY (13).
6b. Mount POWER SUPPLY (13) onto ELECTRICAL BOX (12).
Connect connections to POWER SUPPLY CONNECTIONS
(14). Fig. 2c.
7b. Connect the 10' EXTENSION (10b) to the POWER SUPPLY
CABLE (15). Fig. 2c.
Fig. 2
10a
7
2
2
Fig. 2b
2
3
1
6
9
FROM ELECTRICAL BOX
WITH POWER SUPPLY
Fig. 2c
FOR HARDWIRE HOOK-UP ONLY;
FOR PLUG-IN HOOKUP ONLY
BLACK & WHITE
POWER
CONNECTIONS
10' EXTENSION
13
12
10b
15
14
Fig. 2a
16
6
9
810
2
PLUG INTO
WALL OUTLET
7
16