TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Does not flush a. Water supply valve closed. a. Open valve and allow water to fill tank.
b. Supply line blocked. b. Shut off water supply, disconnect supply line, and inspect
all gaskets and washers. Reassemble. Also, see Fluidmaster
maintenance (see step 13).
c. Push button not properly set. c. Readjust push button rod length as required. Refer to step 12.
d. Sand or debris lodged in water control. d. Shut off water supply. Remove cap and clean per Step 13.
Poor or sluggish flush a. Bowl water level too low. a. Check that refill tube is connected to water control and
inserted into refill float without being kinked or damaged.
b. Supply valve partly closed. b. Open supply valve fully. Be sure that proper supply tube size is used.
c.
Partially clogged trapway and/or drain pipe and/or vent.
c. Remove obstruction. Consult a plumber if necessary.
d. Supply pressure too low. d. Normal supply pressure must be at least 20 psi.
Toilet leaks a. Poor supply line connection. a. Review Step 9 of installation procedure.
b. Poor bowl to tank/floor connection. b. Review Step 4 through 7 of installation procedure.
Toilet does not shut off a. Push button rod is too long, holding flush valve open. a. Readjust rod as needed. Review step 12.
b. Flush valve seat and/or seal worn or deformed. b. Replace seal/flush valve assembly, as needed.
c. Sand or debris lodged in water control. c. Shut off water supply. Remove cap and clean per Step 13.
- 4 -
Make sure water supply is off.
Remove valve TOP by lifting arm
and rotating top and arm 1/8 turn
counterclockwise, pressing down
slightly on cap.
IMPORTANT: Always clear
sand and rust from system.
While holding a container
over the uncapped VALVE to
prevent splashing, turn water
supply on and off a few times.
Leave water supply off.
Replace TOP by engaging lugs
and rotating 1/8 turn clockwise.
MAKE CERTAIN TIP IS TURNED
TO THE LOCKED POSITION.
VALVE MAY NOT TURN ON IF
TOP IS NOT FULLY TURNED TO
THE LOCKED POSITION.
For troubleshooting information please contact:
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK
SLOWLY, repeat Step 13.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF
NON-USE, it is a signal you are wasting water because:
The end of the refill tube is inserted into overflow pipe, below
water level in tank. Attach refill tube to overflow pipe using "S"
clip provided.
The flush valve is leaking because it's worn, dirty or misaligned
with tank ball or flapper (replace with a new flapper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF
TANK WATER IS SLOW after valve has been in use for some
time, Fluidmaster Model 242 Replacement Seal may be needed.
Go to our website at www.fluidmaster.com for more solutions
to toilet problems.
© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products.
Fluidmaster shall not be responsible or liable for any damages caused by products used with
Fluidmaster valves that were not manufactured by Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000 (800) 631-2011
www.fluidmaster.com
LIFT ARM
FIRST
NOTE: Pictures are representative and may not
exactly depict the flush valve.
REPAIR PARTS LIST
Repair parts are determined by toilet tank number which can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options. Specify when ordering.
PART NO. DESCRIPTION
TANK NUMBER
735138-400-XXX
7381092-200.XXX0A
7381091-400.0070A
7381091-401.0070A
738565-429.0070A
738657-100.0070A
738657-101.0070A
7381042-0070A
034783-XXX0A
7301476-100.0070A
TANK COVER
RECTANGLE PUSH BUTTON
DUAL FLUSH VALVE
DUAL FLUSH VALVE
FLUIDMASTER BASE VALVE 12"
REFILL TUBE
REFILL TUBE
FLUSH VALVE SILICONE SEAL
BOLT COUPLING KIT
TANK COUPLING KIT
4349.216
4348.216
4339.216
Without Liner
4349.516
4348.516
4339.516
With Liner