Replacement Part List

7301457-100 Rev. B
Does not
flush
Poor or
sluggish
flush
Toilet leaks
Toilet does not
shut off
Please refer to
the Installation
Instructions
for detailed
corrective actions.
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
REPAIR PARTS LIST
Repair parts are determined by toilet tank number which can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options. Specify when ordering.
PART NO.
DESCRIPTION
COMBO NUMBER
4216.060.XXX
4216.128.XXX
7381105-XXX0A
7381073-200.XXX0A
738565-445.0070A
738921-101.0070A
738920-100.0070A
7301494-0070A
738916-100.0070A
735149-400-XXX0A
738921-104.0070A
7381043-400.0070A
738565-446.0070A
5214.110.XXX
}
!
Use of in tank cleaning products voids warranty as they may damage
parts and cause leakage that may lead to property damage.
WARNING:
For further assistance please call:
In the USA (800) 442-1902 www.americanstandard-us.com, In Canada (800) 387-0369 www.americanstandard.ca
VALVE
BODY
ADJUSTABLE
HEIGHT
WATER LEVEL
ADJUSTMENT
ROD
TANK
LEVER
FLUSH
VALVE
TOP
ARM
NIPPLE
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
CONE WASHER
FLAPPER
THREADED
SHANK
SHANK
WASHER
COUPLING NUT
(HAND TIGHT ONLY)
FILL
VALVE
FLOAT
CUP
CRITICAL
LEVEL MARK
("C.L.") MUST
BE 1" ABOVE
OVERFLOW
PIPE
REFILL
TUBE
LOCK NUT
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
a. Flush valve chain too tight, holding flush valve open.
b. Flush valve seat and/or flapper worn or deformed.
c. Sand or debris lodged in water control.
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets and
washers. Reassemble. Also, see Fluidmaster maintenance. (see Step 13)
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 13.
a. Check that refill tube is connected to water control and inserted into tank
overflow without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Step 9 of installation procedure.
b. Review Step 4 through 7 of installation procedure.
a. Readjust chain length as needed. Review Step 10.
b. Shut off water supply. Replace flush valve.
c. Shut off water supply. Remove cap and clean per Step 13.
TOWN SQUARE TANK - 1.6 gpf (with valves and lever)
TOWN SQUARE TANK - 1.28 gpf (with valves and lever)
TRIP LEVER
BOLT CAP KIT
FLUIDMASTER 400A VALVE INLET VALVE
FLUSHVALVE ASSEMBLY - 3 INCH (INCLUDES FLAPPER)
FLAPPER ASSEMBLY - 3 INCH
TANK COUPLING KIT #261
REFILL TUBE - 5 INCH
TANK COVER - 12" ROUGH
FLUSHVALVE ASSEMBLY (HET) - 3 INCH (INCLUDES FLAPPER)
FLAPPER ASSEMBLY (HET) - 3 INCH
FLUIDMASTER 400A VALVE INLET VALVE
SLOW CLOSE TRADITIONAL EL SEAT
2817
1.6 gpf
2817
1.28 gpf