Installation Guide

754818-100 Rev. A
23
OWNER’S MANUAL
WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
To reduce the risk of injury, keep all components in a vented enclosure and out of the reach of children.
Risk of Electrical Shock – Connect only to a grounding type receptacle protected by a ground fault circuit
interrupter (GFCI).
Verify all components are installed to dedicated circuit(s) with the recommended electrical rating.
All the components are manufactured with 36" pigtail cord and designed to be plugged directly into a ground
fault circuit interrupter (GFCI).
DO NOT CUT OR SPLICE INTO THE COMPONET(S) 3 FOOT PIGTAIL CORD(S).
All components are designed for indoor use on a whirlpool tub.
QUICK DRAIN
®
PUMP
MOTOR WILL NOT START – CHECK FOR:
Quick Drain Control Button should be illuminated. If not , verify the following
a. The pump is plugged into the control box.
b. The control box is plugged into the outlet.
c. The control button is plugged into the control box.
Improper or loose connections, open switches or relays, blown circuit breakers.
Manually check rotation of motor shaft for free movement and obstruction.
MOTORS CUTS OUT – CHECK FOR:
Wiring, loose connections etc.
Low Voltage at motor. (Frequently caused by undersized wiring.)
Binding or overload. (Amperage Reading.)
MOTOR HUMS, BUT WILL NOT PRIME – CHECK FOR:
Make sure all suction, discharge lines and valves are open and un-obstructed.
Check for correct water level.
Block off suction and determine if pumps develops a vacuum. If pump develops a vacuum check
discharge line for obstruction or a leak in the suction line.
If the pump does not develop a vacuum and the pump has the correct water level, check for proper
voltage and / or check the pump wet end for clogging or debris
TROUBLE SHOOTING GUIDELINES
!
!
!
!
!