Installation Guide

5
4
SERVICE
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Pull out INDEX CAP (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3).
Pull off STEM ADAPTER (4).
Remove SPRING CLIP (6).
Lift STOP WASHER (5), turn 90˚ and replace.
Replace SPRING CLIP (6) and STEM ADAPTER (4).
Reinstall HANDLE ASSEMBLY (1,2 & 3).
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90˚.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections. Do not over
tighten. For BULL-NOSE RISERS (3), be careful not to kink copper
supply when bending. Use of tubing cutter may be required to cut
to proper length.
MAKE WATER SUPPLY CONNECTIONS
2
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
1
2
4
5
3
90˚
6
3
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water lines thoroughly.
Rotate SPOUT (5) in both directions.
Replace AERATOR (3).
Direct SPRAY (4) into sink and activate. Check hose
connections for leaks.
1
3
2
1
5
4
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE:
M965459 Rev. 1.2
FERRULE
COUPLING NUT
1
2
1
3
3