Installation Guide

- 3 -
6
7
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
5
M985012 (3/19)
1
3
2
4
5
REMOVE
COLD
ON
OFF
HOT
SERVICE
1
2
3
5
7
5a
4
6
TEST INSTALLED FAUCET
Move HANDLE (1) into “off” position.
Turn on water supplies.
Check connection for leaks. (See Section 4)
With HANDLE (1) in “off” position, unthread
SPRAY (3) from HOSE (2).
Operate handle back to front, in COLD
and HOT positions, to ush water lines
thoroughly.
• Replace SPRAY (3) onto HOSE (2).
If Faucet Drips, Proceed As Follows:
• Turn VALVE to OFF position.
Operate HANDLE several times from OFF to ON position. Do not apply excessive force.
Reduced Flow:
• Clean out spray head screen.
Clean out cartridge.
Clogged CARTRIDGE outlets or inlets may
cause reduced flow.
To clean, rst turn off water supply then:
Loosen HANDLE SCREW (1) and remove
HANDLE (2).
Unthread ESCUTCHEON CAP (3),
SNAP RING (4).
Lift CARTRIDGE (5) off MANIFOLD (6) and
remove CARTRIDGE SEALS (7).
Clean MANIFOLD (6), CARTRIDGE (5)
ports and SEALS (7).
Place SEALS (7) into CARTRIDGE
PORTS (5a).
Place CARTRIDGE (5) onto
MANIFOLD (6).
Replace ESCUTCHEON CAP (3), SNAP RING (4),
HANDLE (2), tighten HANDLE SCREW (1).