Installation Guide

6
7
If Faucet Drips, Proceed As Follows:
• Turn VALVE to OFF position.
Operate HANDLE several times from OFF to ON position. Do not apply excessive force.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, rst turn off water supply then:
Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).
Unthread ESCUTCHEON CAP (4). Unthread three MOUNTING SCREWS (5).
Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (8).
Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).
• Place SEALS (8) into CARTRIDGE PORTS (6a).
Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING SCREWS (5) alternately.
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE SCREW (2) and install INDEX BUTTON (1).
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
SERVICE
CARE:
M965801 Rev.1.1 (7/17)
6
8
6a
7
1
2
4
5
3
- 4 -