Installation Guide

Fig.7
CONVERT RIGID GOOSENECK
SPOUT TO SWING SPOUT; Fig. 6
The GOOSENECK SPOUT is shipped from the
factory as a rigid assembly. To convert the
GOOSENECK SPOUT into a SWING SPOUT, proceed
as follows:
1. Remove SET SCREW (1) from back of GOOSENECK
SPOUT (2) with a flat blade screwdriver. Fig. 6.
2. Install SWIVEL SET SCREW (3) on the back of
GOOSENECK SPOUT (2). SWIVEL SET SCREW (3)
is found in hardware bag inside the product box.
F
Fig.6
1
2
3
(USE SHORT
SET SCREW
FOR SWIVEL
SPOUT)
M965650 Rev. 1.3 (8/15)
9
FAQ'S
Q: How will I know if the battery needs to be replaced?
A: Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced significantly?
A: The filter assembly, flow regulator or areator/spray may be clogged. Check and clean. Refer to Start-up/Mainenance,
sections C, D and E.
Q: Why doesn’t the water flow out of faucet when I'm within the sensor detection zone?
A: Battery may need replacement. Check. If sensor continuously blinks 2 times interrupted by pause, replace battery
or call (844) CRT-TEAM / (844) 278-8326.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging from 20-80 psi.
CAUTION
GENERAL CLEANING; Fig. 7
1. Only use a damp, soft cloth to clean the spout and
the sensor.
2. For tougher dirt, use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using any abrasives or harsh detergents
or chemicals.
G