INSTALLATION AND OPERATION MANUAL FOR EVERCLEAN™/EVOLUTION™ AIR BATHS MODEL 2422L.068C 2422V.068C 5' x 32" MODEL 2771L.068C 2771V.068C 5' x 36" MODEL 2645L.068C 2645V.068C OVAL MODEL 7236L.068C 7236V.068C 6' x 36" MODEL 2425L.168C 2425V.168C 5' x 32" IA-RHO MODEL 2425L.268C 2425V.268C 5' x 32" IA-LHO THANK YOU... for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The air bath is completely assembled with air blower and system piping.
TABLE OF CONTENTS: Safety Instructions............................................................................Page 3 General Information..........................................................................Page 4 Optional Components.......................................................................Page 4 Specifications....................................................................................Page 5 Roughing-in Reference................................................................
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS! ! WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision. ! WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting. ! WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within 60 inches (1524mm) of this unit.
General Installation Information Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling! Do not make unauthorized modifications to the air bath system.
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR EVOLUTION AIR BATHS Description Dimensions L-W-H Drain / Height to Cut Out Overflow Underside Pier of Deck: C GxF Rough-In Tub Edge to Weight with Product Apron / Gallon to Recess Centerline Water / Floor Weight Mounting Overflow ExD Overflow: J Loading 2422L / V.
ROUGHING-IN REFERENCES 6' x 36" (MODEL 7236L / V.068C) 5' x 32" (MODEL 2422L / V.068C) 72" (1829mm) 60" (1524mm) 13-3/4" (349mm) 3" (76mm) 32" (813mm) 6" (152mm) CUT OUT IN FLOOR FOR DRAIN 3-1/4" (83mm) 13-3/4" (349mm) 36" (914mm) 6" (152mm) 7-3/4" (197mm) CUT OUT IN FLOOR FOR DRAIN 11" (279mm) 3-1/4" (83mm) 5' x 36" (MODEL 2771L / V.068C) 60" (1524mm) 7-3/4" (197mm) 3" (76mm) 11" (279mm) 11" (279mm) OVAL (MODEL 2645L / V.
INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this air bath may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the air blower and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening. 1.
TYPICAL FLANGE MOUNTING DETAIL SUGGESTED AIR BATH / BATH INSTALLATION METHOD WOOD STUDS STEEL STUDS STEEL STUD STUD WATERPROOF DRYWALL OR CEMENT BOARD TILE WASHER WATERPROOF DRYWALL OR CEMENT BOARD TILE ROOFING NAIL SEALANT SEALANT 4" (102mm) DRYWALL SCREW TUB TUB 1" x 3" (25 x 76mm) WOOD STRINGER FULL LENGTH 1" x 3" (25 x 76mm) WOOD STRINGER FULL LENGTH SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION.
AIR BATH ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. ! WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Permit access for servicing blower as noted. 3.
REMOTE BLOWER LOCATION OPTION IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical. NOTE: Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired position of air blower. Follow all instructions listed below.
POST INSTALLATION CLEAN-UP Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface. Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water. Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
Operation: Air Bath BATHING: • Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE • Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired. OPERATING AIR MASSAGE SYSTEM: ON/OFF: Press this button once to turn air-blower on. Press again to turn air-blower off. AIR SPEED INCREASE: Pressing this button will increase to the next higher speed. AIR SPEED DECREASE: Pressing this button will decrease to the next lower speed.
Your American Standard whirlpool is designed to give you many years of pleasure with reasonable care and maintenance. Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its lasting luster with proper care and maintenance. CLEANING AND MAINTENANCE: • Always fill the tub with temperate water.
AS America, Inc. Limited Lifetime Warranty For Lifetime™/Evolution™ Acrylic Air Baths AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this air bath or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser.