RECOMMENDED TOOLS
1
INSTALL SPOUT
Townsend
®
Roman Tub Filler
INSTALLATION
INSTRUCTIONS
T353900
T353901
Certied to comply with ANSI A112.18.1M
CAUTION
Turn off hot and cold water
supplies before begining.
M965951 (8/18)
434 mm
(17")
280 mm
(11")
253 mm
(10")
116 mm
(5")
215 mm
(8-1/2")
198 mm
(8")
99 mm
(4")
102 mm
(4")
1" MAX.
(25 mm)
8" TO 16"
FLEXIBLE INSTALLTION
(203 TO 406 mm)
Adjustable Wrench
Channel Locks
Flat Blade Screwdriver
Phillips Screwdriver
Hex Wench
(supplied)
Hex wench
(supplied)
3
4
6
RECESS
MOUNTING
SURFACE
1
5
2
7
ROUGHING-IN
DIMENSIONS
Apply 4-5 drops of THREADLOCKER (1)
on DIVERTER INSERT (2) threads (supplied).
NOTE: If installing on nished deck, install DIVERTER
INSERT (2) through WASHER (7).
Thread DIVERTER INSERT (2) carefully until it touches the
installation surface, be sure the RUBBER RING (5)
is properly seated in it’s RECESS at the base of the
SPOUT (3).
Thread SET SCREW (4) using 5 mm hex wrench supplied.
Make certain SET SCREW (4) is properly aligned and tight
so that SPOUT (3) is locked in place.
Install PLUG BUTTON (6).