Service manual

S-311
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service); +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
Revised 03/2006
1-12
3. CONNECTION OF THE MACHINE HEAD WITH THE CONTROL BOX
3.1. The control box Ê contains the control system, regulator Ë and valve terminal Ì for
controlling the pneumatic cylinders.
B - MACHINE ASSEMBLY
3.2. The machine is connected from the plant. If disassembled, connect the machine as follows:
- blue pneumatic tubes J1A/B — J9A/B connect with equally marked electromagnetic valves.
- cables for stepping motors marked X, Y, R, T connected with equally marked cables.
- remaining cable is used for sensor and switches connection with box.