20. CHANGING THE SETTINGS
$
When the distance measurement mode is set to "Tracking" (target is moved during distance
measurement) the EDM ALC will be adjusted regardless of the EDM ALC setting.
& Laser-pointer off
To save power, the laser-pointer is automatically turned off after the set time has elapsed.
& Key backlight
The key backlight can be set to "ON" or "OFF". When "ON" the keys will be illuminated when
"Backlight (Bright)" is active.
• "EDM" tab
Items set, options, and input range (*: Factory setting)
Dist. mode (Distance measurement mode): Fine “R”*, Fine AVG n= 1(Setting: 1 to 9 times), Fine
“S”, Rapid "R", Rapid “S”, Tracking
Reflector: Prism*/Sheet/N-Prism
Prism constant: -99 to 99 mm ("Prism" is selected: 0*, "Sheet" is
selected: 0)
Illum. hold ({J} function): Laser-pointer*/Guide light
Guide light (Bright): 1 to 3 (3*)
The setting for "Fine AVG" distance measurement mode can be increased/decreased using the
[ + ]/[ - ] softkeys.
Target information can be edited and recorded.
C"PROCEDURE Recording and editing target information"
"Prism constant" will not be displayed when "N-Prism" is selected in "Reflector".
When "prism constant" values are changed and [OK] is pressed, these changes are reflected
in the status bar target type display temporarily. This display will also change to reflect changes
in target information settings made using a data collector temporarily. In both of the above cases,
changes will not be recorded in <Reflector setting>.
CStatus bar: "5.2 Display Functions", <Reflector setting>: "PROCEDURE Recording and
editing target information", Cold boot: "9.2 Resolving Software Issues D Cold boot"
The Guide light brightness item ("Guide light (Bright)") will be displayed only when "Illum. hold"
is set to "Guide light".
20.3